TROUBLE-SHOOTING
10/12
23
Fault condition 7
The mc 25 works too slow but counter works.
Remove mains fuses, disconnect the
mc 25 from mains!
Pull out mains plug (1).
Unscrew the fuse holder (2).
Check the device fuses (3).
Replace defective device fuses. The corre-
sponding article number is stated in chapter
spare parts.
Insert device fuses into the fuse holder.
Insert the fuse holder.
Fault condition 8
Crimp stamp or crimp forging die is defective.
Open the cover and disconnect the
mc 25 from mains supply!
Pull out mains plug (1).
Remove tool insert and end-sleeves feeder (see
also chapter
retooling
).
Unscrew the allen screw (3) at defective crimp
stamp (2) or crimp forging die (1).
Press the ring (4) down and remove the hose.
Replace the defective part.
The corresponding article number is stated in
chapter
spare parts.
Plastic parts must be clean and free of
grease!
Diagram 30
Check device fuses
Diagram 31
Replace crimp stamp /
crimp forging die
Содержание MC 25
Страница 2: ...MC25...
Страница 3: ...MC25 Betriebsanleitung MC 25 Ausgabedatum 01 2020 F r k nftige Verwendung aufbewahren...
Страница 4: ...MC25...
Страница 6: ...10 12...
Страница 35: ...MC 25 Instruction for use MC 25 Date of issue 01 2020 Save this instruction for further use...
Страница 36: ...MC 25...
Страница 38: ...10 12...
Страница 67: ...Instructions d emploi MC 25 Date d dition 01 2020 A conserver pour utilisation ult rieure...
Страница 68: ......
Страница 70: ...10 12...
Страница 99: ...Manual de instrucciones MC 25 Fecha de edici n 01 2020 Guarde estas instrucciones para su uso posterior...
Страница 100: ......
Страница 102: ...10 18...