OPERATION
10/12
13
4. Crimping cables
Insert the cable (1) straight into the funnel guide
until it stops.
Crimping and stripping works automatically.
Pull out the cable (2) straight when the mc 25
has stopped.
!
Refer to chapter faults when operating
faults or unsuccessful crimping
occurs.
Read counter (3) if required and set it to 0 with
the reset button (4).
5. Stop operation
Read counter (1) if required.
Turn off (position 0) the mc 25 with the mains
switch (2).
6. Daily maintenance
Disconnect the mains supply from the
mc 25 and open cover.
Turn off (position 0) the mc 25 with mains
switch (1).
Disconnect mains cable (2).
Slide the cover (3) back.
Remove (4) insulation scraps inside the mc 25.
Pull out the container (5).
Dispose insulation scraps and insert container.
Close the cover (6).
Connect mains cable (7).
Diagram 13
Crimping cables
Diagram 14
Stop operation
Diagram 15
Daily maintenance