GLP Ipression XL Скачать руководство пользователя страница 17

 

R

R

R

-

-

-

G

G

G

-

-

-

B

B

B

 

 

GLP 

 German Light Products GmbH 

(Manual Version 1.06) / from Software Version 1.09/0.3)

 

17

 

c)  Standard Mode (Hold down the ENTER- button during power ON)  

After switching on the fixture, the DMX start address will be set to [001]. All other settings 

will remain unchanged.  

 

Additional Display Indications  

As a default you'll find the following additional information in the first row of the LCD display:  

XX/X/XX 
 

06 = 600Hz / 12 = 1200Hz 

 

N = Normal Mode / C = Compressed Mode / H = High Res. Mode 

 

N = Tilt normal / I = Tilt inverted  

 

N = Pan normal  / I = Pan inverted  

 

5

5

 

  Maintaining and Cleaning the 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

X

X

L

L

 

 

 

 

The 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

X

X

L

L is a low maintenance fixture. It is only necessary to clean the 

air  inlets  and  outlets  as  well  as  the  optical  LED  lenses  from  time  to  time.  For  safe 

operation it is absolutely essential that the fixture is kept clean and that dust, dirt and 

smoke-fluid  residues  must  not  build  up  on,  or  within,  the  fixture.  If  they  do,  the 

fixture's  light  output  will  be  significantly  reduced,  and  damages  to  the  fixture  may 

occur.  Regular  cleaning  will  not  only  ensure the maximum  light  output, but  will  also 

allow the fixture to operate reliably throughout its entire life.  

A  soft  lint-free  cloth  moistened  with  any  good  glass  cleaning  fluid  is  recom-

mended. Under no circumstances should alcohol or solvents be used to clean 

the fixture or its lenses! 

 

5.1  Safety regulations 

 

Disconnect the fixture from the mains power before commencing any maintenance 

work! 

 

Wait minimum 15 minutes after removing the power to allow the fixture to cool down. 

5.2  Maintenance Intervals (rule-of-thumb) 

The maintenance schedule of any given fixture depends on the installation environment. Hence 

no specific guidelines can be given. The cleaning intervals given below are suggestions, based 

on  practical  experience.  We  suggest  that  you  start  with  these  and  develop  your  own 

maintenance schedule as you see the fixtures performance in your specific environment.  

Maintenance Task 

Interval 

How 

Cleaning  of  LED  lenses  and 
optical system 

weekly 

soft brush /lint-free cloth 

Содержание Ipression XL

Страница 1: ...Instruction Manual from Software Version 1 09 0 3 Manual Version 1 06 e mail service glp de Internet http www glp de...

Страница 2: ...R R R G G G B B B GLP German Light Products GmbH Manual Version 1 06 from Software Version 1 09 0 3 2 For your notes...

Страница 3: ...1 Mounting on the floor upright 7 2 1 2 Mounting in hanging position Head down 7 2 1 3 Mounting in sideway position 8 2 2 Securing the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9 3 Th...

Страница 4: ...the tilt movement see also 1 1 4 LCD Display Menu data entry 5 Base with various connectors and Camlock mounting system Safety eyelets 1 2 4 5 3 base side 1 10 6 7 8 9 10 base side 2 11 12 13 14 6 DM...

Страница 5: ...ranty 6 Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay attention to possible hot parts of the system 7 Never look di...

Страница 6: ...Installation 2 1 Mounting The I IM MP PR RE ES SS SI IO ON N X XL L is fully operational whether it hangs or is mounted to a wall It can also be operated while standing on the floor Keep a safety dist...

Страница 7: ...k quarter turn fasteners Line up and engage the camlock connectors from the floor stand into the base of the fixture and turn the two fasteners 90 to lock them Do the opposite to release them again On...

Страница 8: ...or one of their agents This mounting bar is fixed via the four camlock quick release connectors Two half couplers or clamps are then used to hang the mounting bar This technique is necessary to cope w...

Страница 9: ...he fixture and the fixtures mounting support Install a safety wire that can hold at least 10 times the weight of the fixture 2 3 Connections 2 3 1 Power Supply 100 240 Volt AC 50 60 Hz earth contact t...

Страница 10: ...l of all system functions Pan Manual control for Pan X movement Speed Movements Speed adjustment for Pan Tilt movements see also item below Pan Tilt Movements Manual control for Pan Tilt movement Spec...

Страница 11: ...lt ON or OFF disconnected from power PAN TILT Silent Mode Reduces maximum speed for Pan Tilt DMX Hold Defines whether the last DMX signal is stored or the lamp is switched OFF in case of signal interr...

Страница 12: ...lution mode see also section 4 White Mode ON OFF Adjustments for white balance are activated Reverse Pan Selects Inverse Pan on or off Reverse Tilt SelectsInverse Tilt on or off Reset RESET all functi...

Страница 13: ...dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast...

Страница 14: ...l is set to a value between DMX 16 31 the white balance is used for the RGB output Since there is no Special DMX channel in the Compress DMX Mode the possibility exists to likewise select these settin...

Страница 15: ...ing random patterns slow fast 48 79 30 4F 19 31 5 Shutter open then down dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56...

Страница 16: ...bow effect synchronously Different I IM MP PR RE ES SS SI IO ON N X XL L can have different start colors but will still execute the rainbow effect synchronously If you choose a color different from th...

Страница 17: ...within the fixture If they do the fixture s light output will be significantly reduced and damages to the fixture may occur Regular cleaning will not only ensure the maximum light output but will als...

Страница 18: ...r supply Power consumption 1200 VA Watt Power Input 100 240 V AC 50 60 Hz auto sensing input Fuse protection Micro fuse 6 3x32 mm T15A Operational Parameters Max Ambient Temperature 45 C 113 F integra...

Страница 19: ...nd Random Strobe Pulse Effects Continuous Dimmer 0 100 DMX Control Standard USITT DMX 512 3 5 pole XLR Pin 3 Pin 2 Ground Pin 1 DMX Addressing starts at the DMX channel 001 Pan Tilt 8 16 Bit Pan movem...

Страница 20: ...ED Class 2M 5 M Maintenance 16 Manual Version 1 Max Power Mode 13 Micro fuse 8 Mode key 9 Mounting 6 Mounting in hanging Position 7 Mounting in sidewise Position 8 Mounting on the Floor 6 N Normal Mod...

Страница 21: ...R R R G G G B B B GLP German Light Products GmbH Manual Version 1 06 from Software Version 1 09 0 3 21...

Отзывы: