GLP Ipression XL Скачать руководство пользователя страница 10

 

R

R

R

-

-

-

G

G

G

-

-

-

B

B

B

 

 

GLP 

 German Light Products GmbH 

(Manual Version 1.06) / from Software Version 1.09/0.3)

 

10

 

The Menu Field

 

You’ll  find  the  control  board  on  the  side  of  the  arm.  It  allows 
you  to  make  all  necessary  adjustments  of  the 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

X

X

L

L

.

.

 

  With  the  Mode-key  you  get  into  the  main  menu. 

Afterwards  you  can  navigate  through  the  menu  with  the 
Up/Down-keys.  Push  the  Enter-key  to  get  to  the  next  menu 
level  or  to  confirm  your  settings.  Select  ON/  OFF  function 
settings  with  the  Up/Down-keys.  Confirm  and  save  with  the 
Enter-key  (the  display  shows  OK).  Push  the  Mode-key  to 
cancel the entry and go back to the main menu. 

Mode

Scroll wheel - Up & Down

Enter

 

 

 D

O

W

N

  

 U

P

 

 

 MODE - ENTER 

 

 

Level1 

Level 2 

Level 3 

Level 4 

Remark 

DMX Start 
Address 
001 

 

 

 

Define the DMX start address 

Special 

Manual DMX 

 

 

Manual control of all system functions 

 

 

Pan 

 

Manual control for Pan (X-movement)  

 

 

Speed 
Movements 

 

Speed adjustment for Pan/Tilt movements 

 

see also item below 

 

 

Pan/Tilt 
Movements 

 

Manual control for Pan/Tilt movement 

 

 

Special 

 

Activate the White- or Full-Power Mode; see 
also DMX table 

 

 

White 
Temperature 

 

Adjustment of the white color temperature  

 

 

Dimmer 

 

Manual control for dimmer  

 

 

Shutter 

 

Manual control for shutter 

 

 

Blue 

 

Manual control for blue 

 

 

Green 

 

Manual control for green 

 

 

Red 

 

Manual control for red 

 

 

Color Wheel 

 

Manual control for the color wheel 

 

 

Tilt 

 

Manual control for tilt (Y-movement)  

 

Display 
Contrast 

 

 

Adjustment for the Display contrast  

 

Default Set 

 

 

Resetting all functions to original values 

 

Set Dimmer 
Frequency 

 

 

Changes PMW frequency between 600Hz and 
1200Hz 

 

LED Dimmer 
Version 

 

 

Reads out the current LED dimmer (software) 
version 

 

ImpressionXL 
Version 

 

 

Reads out the current CPU software version 

 

Adjust 

Key code 
xxxx 

 

Use the code for entering the calibration menu 
(for authorized persons only)  

 

 

Pan Offset 

 

Calibration for Pan-Offset 

Содержание Ipression XL

Страница 1: ...Instruction Manual from Software Version 1 09 0 3 Manual Version 1 06 e mail service glp de Internet http www glp de...

Страница 2: ...R R R G G G B B B GLP German Light Products GmbH Manual Version 1 06 from Software Version 1 09 0 3 2 For your notes...

Страница 3: ...1 Mounting on the floor upright 7 2 1 2 Mounting in hanging position Head down 7 2 1 3 Mounting in sideway position 8 2 2 Securing the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9 3 Th...

Страница 4: ...the tilt movement see also 1 1 4 LCD Display Menu data entry 5 Base with various connectors and Camlock mounting system Safety eyelets 1 2 4 5 3 base side 1 10 6 7 8 9 10 base side 2 11 12 13 14 6 DM...

Страница 5: ...ranty 6 Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay attention to possible hot parts of the system 7 Never look di...

Страница 6: ...Installation 2 1 Mounting The I IM MP PR RE ES SS SI IO ON N X XL L is fully operational whether it hangs or is mounted to a wall It can also be operated while standing on the floor Keep a safety dist...

Страница 7: ...k quarter turn fasteners Line up and engage the camlock connectors from the floor stand into the base of the fixture and turn the two fasteners 90 to lock them Do the opposite to release them again On...

Страница 8: ...or one of their agents This mounting bar is fixed via the four camlock quick release connectors Two half couplers or clamps are then used to hang the mounting bar This technique is necessary to cope w...

Страница 9: ...he fixture and the fixtures mounting support Install a safety wire that can hold at least 10 times the weight of the fixture 2 3 Connections 2 3 1 Power Supply 100 240 Volt AC 50 60 Hz earth contact t...

Страница 10: ...l of all system functions Pan Manual control for Pan X movement Speed Movements Speed adjustment for Pan Tilt movements see also item below Pan Tilt Movements Manual control for Pan Tilt movement Spec...

Страница 11: ...lt ON or OFF disconnected from power PAN TILT Silent Mode Reduces maximum speed for Pan Tilt DMX Hold Defines whether the last DMX signal is stored or the lamp is switched OFF in case of signal interr...

Страница 12: ...lution mode see also section 4 White Mode ON OFF Adjustments for white balance are activated Reverse Pan Selects Inverse Pan on or off Reverse Tilt SelectsInverse Tilt on or off Reset RESET all functi...

Страница 13: ...dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast...

Страница 14: ...l is set to a value between DMX 16 31 the white balance is used for the RGB output Since there is no Special DMX channel in the Compress DMX Mode the possibility exists to likewise select these settin...

Страница 15: ...ing random patterns slow fast 48 79 30 4F 19 31 5 Shutter open then down dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56...

Страница 16: ...bow effect synchronously Different I IM MP PR RE ES SS SI IO ON N X XL L can have different start colors but will still execute the rainbow effect synchronously If you choose a color different from th...

Страница 17: ...within the fixture If they do the fixture s light output will be significantly reduced and damages to the fixture may occur Regular cleaning will not only ensure the maximum light output but will als...

Страница 18: ...r supply Power consumption 1200 VA Watt Power Input 100 240 V AC 50 60 Hz auto sensing input Fuse protection Micro fuse 6 3x32 mm T15A Operational Parameters Max Ambient Temperature 45 C 113 F integra...

Страница 19: ...nd Random Strobe Pulse Effects Continuous Dimmer 0 100 DMX Control Standard USITT DMX 512 3 5 pole XLR Pin 3 Pin 2 Ground Pin 1 DMX Addressing starts at the DMX channel 001 Pan Tilt 8 16 Bit Pan movem...

Страница 20: ...ED Class 2M 5 M Maintenance 16 Manual Version 1 Max Power Mode 13 Micro fuse 8 Mode key 9 Mounting 6 Mounting in hanging Position 7 Mounting in sidewise Position 8 Mounting on the Floor 6 N Normal Mod...

Страница 21: ...R R R G G G B B B GLP German Light Products GmbH Manual Version 1 06 from Software Version 1 09 0 3 21...

Отзывы: