GLP Ipression XL Скачать руководство пользователя страница 13

 

R

R

R

-

-

-

G

G

G

-

-

-

B

B

B

 

 

GLP 

 German Light Products GmbH 

(Manual Version 1.06) / from Software Version 1.09/0.3)

 

13

 

Channel 

Function 

Time and Value 

DMX 

HEX 

 

Color 10 - Mauve 

1)

 

 

80..87 

50..57  31..34,5 

 

Color 11 - Magenta 

1)

 

 

88..95 

58..5F  35..37,5 

 

Color 12 - Pink 

1)

 

 

96..103 

60..67  38..40,5 

 

White - CTO 

Color temperature 
3200K 

104..111  68..6F  41..43,5 

 

White 

Color temperature 
5600K 

112..119 

70..77  44..46,5 

 

White - CTB 

Color temperature 
7200K 

120..127  78..7F  47..49,5 

 

Rainbow Effect Stop 

2)

 

 

128 

80 

50 

 

Rainbow Effect 

3)

 

slow - fast 

129..223  81..DF 

51..88 

 

Rainbow Effect, random colors 

slow - fast 

224.255 

E=..FF  89..100 

6) Red 

Color mixing system - Red 

0 - 100% 

0..255 

00..FF 

0..100 

7) Green 

Color mixing system - Green 

0 - 100% 

0..255 

00..FF 

0..100 

8) Blue 

Color mixing system - Blue 

0 - 100% 

0..255 

00..FF 

0..100 

9) Shutter 

Shutter closed 

 

0..15 

00..0F 

0..5,5 

 

Random Pulse effect 

slow - fast 

16..47 

10..2F 

6..18,5 

 

Up-dimming then Shutter closing 
(random patterns)  

slow - fast 

48..79 

30..4F 

19..31 

 

Shutter open then down-dimming 
(random patterns) 

slow - fast 

80..111 

50..6F 

32..43 

 

Up-dimming then down-dimming 
(random patterns) 

slow - fast 

112..143  70..8F 

44..56 

 

Strobe effect pause  

5s to 1s 

144..199  A0..C7 

57..77 

 

Strobe effect, slow - fast 

1 Hz .. 10 Hz 

200..239  C8..EF 

78..94 

 

Shutter open 

 

240..255  F0..FF  95..100 

10) Dimmer  Dimmer  

0% - 100% 

0..255 

0..FF 

0..100 

11) Color  

No color temperature correction 

 

0..6 

0..06 

0..2 

temperature  Continuous color temperature 

correction between 3200k - 7200k 

Applicable only for 
White color 

5)

 

7..255 

07..FF 

3..100 

12) Special 

Max. Power-Mode 

4)

  

Max. light output without 
white balance 

0..15 

0..0F 

0..5,5 

 

White-Mode 

4) 

White balance used 

16..31 

10..1F 

6..12,5 

 

Fan min. as long as temp. < 90°C 

 

224..229   E0..E5  88..89,5 

 

RESET (Normal Mode) 

 

250..255  FA..FF  98..100 

13) Move- 

No movement 

 

00 

    ment 

Movement  Size 

Phase 

 

 

 

 

 

PAN 

0° 

 

01..01 

01..01 

0,5 

 

 

90° 

 

02..03 

02..03 

1,0 

 

 

180° 

 

04..05 

04..05 

1,7 

 

 

270° 

 

06..07 

06..07 

2,5 

 

PAN 

0° 

 

08..09 

08..09 

3,3 

 

 

90° 

 

10..11 

0A..0B 

4,1 

 

 

180° 

 

12..13 

0C..0D  

4,9 

 

 

270° 

 

14..15 

0E..0F 

5,7 

 

PAN 

0° 

 

16..17 

11..11 

6,5 

 

 

90° 

 

18..19 

12..13 

7,3 

 

 

180° 

 

20..21 

14..15 

8,0 

 

 

270° 

 

22..23 

16..17 

8,8 

 

PAN 

0° 

 

24..25 

18..19 

9,6 

 

 

90° 

 

26..27 

1A..1B 

10,4 

 

 

180° 

 

28..29 

1C..1D  

11,2 

 

 

270° 

 

30..31 

1E..1F 

12 

Содержание Ipression XL

Страница 1: ...Instruction Manual from Software Version 1 09 0 3 Manual Version 1 06 e mail service glp de Internet http www glp de...

Страница 2: ...R R R G G G B B B GLP German Light Products GmbH Manual Version 1 06 from Software Version 1 09 0 3 2 For your notes...

Страница 3: ...1 Mounting on the floor upright 7 2 1 2 Mounting in hanging position Head down 7 2 1 3 Mounting in sideway position 8 2 2 Securing the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9 3 Th...

Страница 4: ...the tilt movement see also 1 1 4 LCD Display Menu data entry 5 Base with various connectors and Camlock mounting system Safety eyelets 1 2 4 5 3 base side 1 10 6 7 8 9 10 base side 2 11 12 13 14 6 DM...

Страница 5: ...ranty 6 Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay attention to possible hot parts of the system 7 Never look di...

Страница 6: ...Installation 2 1 Mounting The I IM MP PR RE ES SS SI IO ON N X XL L is fully operational whether it hangs or is mounted to a wall It can also be operated while standing on the floor Keep a safety dist...

Страница 7: ...k quarter turn fasteners Line up and engage the camlock connectors from the floor stand into the base of the fixture and turn the two fasteners 90 to lock them Do the opposite to release them again On...

Страница 8: ...or one of their agents This mounting bar is fixed via the four camlock quick release connectors Two half couplers or clamps are then used to hang the mounting bar This technique is necessary to cope w...

Страница 9: ...he fixture and the fixtures mounting support Install a safety wire that can hold at least 10 times the weight of the fixture 2 3 Connections 2 3 1 Power Supply 100 240 Volt AC 50 60 Hz earth contact t...

Страница 10: ...l of all system functions Pan Manual control for Pan X movement Speed Movements Speed adjustment for Pan Tilt movements see also item below Pan Tilt Movements Manual control for Pan Tilt movement Spec...

Страница 11: ...lt ON or OFF disconnected from power PAN TILT Silent Mode Reduces maximum speed for Pan Tilt DMX Hold Defines whether the last DMX signal is stored or the lamp is switched OFF in case of signal interr...

Страница 12: ...lution mode see also section 4 White Mode ON OFF Adjustments for white balance are activated Reverse Pan Selects Inverse Pan on or off Reverse Tilt SelectsInverse Tilt on or off Reset RESET all functi...

Страница 13: ...dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast...

Страница 14: ...l is set to a value between DMX 16 31 the white balance is used for the RGB output Since there is no Special DMX channel in the Compress DMX Mode the possibility exists to likewise select these settin...

Страница 15: ...ing random patterns slow fast 48 79 30 4F 19 31 5 Shutter open then down dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56...

Страница 16: ...bow effect synchronously Different I IM MP PR RE ES SS SI IO ON N X XL L can have different start colors but will still execute the rainbow effect synchronously If you choose a color different from th...

Страница 17: ...within the fixture If they do the fixture s light output will be significantly reduced and damages to the fixture may occur Regular cleaning will not only ensure the maximum light output but will als...

Страница 18: ...r supply Power consumption 1200 VA Watt Power Input 100 240 V AC 50 60 Hz auto sensing input Fuse protection Micro fuse 6 3x32 mm T15A Operational Parameters Max Ambient Temperature 45 C 113 F integra...

Страница 19: ...nd Random Strobe Pulse Effects Continuous Dimmer 0 100 DMX Control Standard USITT DMX 512 3 5 pole XLR Pin 3 Pin 2 Ground Pin 1 DMX Addressing starts at the DMX channel 001 Pan Tilt 8 16 Bit Pan movem...

Страница 20: ...ED Class 2M 5 M Maintenance 16 Manual Version 1 Max Power Mode 13 Micro fuse 8 Mode key 9 Mounting 6 Mounting in hanging Position 7 Mounting in sidewise Position 8 Mounting on the Floor 6 N Normal Mod...

Страница 21: ...R R R G G G B B B GLP German Light Products GmbH Manual Version 1 06 from Software Version 1 09 0 3 21...

Отзывы: