GLP Ipression XL Скачать руководство пользователя страница 12

 

R

R

R

-

-

-

G

G

G

-

-

-

B

B

B

 

 

GLP 

 German Light Products GmbH 

(Manual Version 1.06) / from Software Version 1.09/0.3)

 

12

 

 

 

Shutter 

 

Instantaneous value for shutter 

 

 

 

Blue 

 

Instantaneous value for blue 

 

 

Green 

 

Instantaneous value for green 

 

 

Red 

 

Instantaneous value for red 

 

 

Color Wheel 

 

Instantaneous value for Color Mixing unit  

 

 

Tilt 

 

Instantaneous value for Tilt movement  

Live time 

 

 

 

Indicates the overall operation time of the 
system 

 

Display 

 

 

 

Adjust the display 

 D

O

W

N

  

 U

P

 

 

 

Blackout 

 

 

ON/OFF: Display OFF 

Select DMX 
Mode 

 

 

 

Please select the desired DMX Mode 

 

Compressed  

 

 

Fixture works in "Compressed" mode 

 see 

also sectiion 4 

 

Normal  

 

 

Fixture works in "Normal" mode 

 see also 

section 4 

 

High-
Resolution  

 

 

Fixture works in "High Resolution" mode 

 see 

also section 4 

White 
Mode 

 

 

 

ON/OFF: Adjustments for white-balance are 
activated  

Reverse 
Pan 

 

 

 

Selects Inverse Pan, on or off 

Reverse 
Tilt 

 

 

 

SelectsInverse Tilt on or off 

 

Reset 

 

 

 

RESET all functions  

 

 

4  DMX Channel Sheet  

Normal-Mode 14 DMX channels 

Channel 

Function 

Time and Value 

DMX 

HEX 

1) PAN-
  coarse 

0 .. 660° 

 

0..255 

00..FF 

0..100 

2) PAN-fine 

High- Pos ... High- Pos + 2,6° (16 Bit) 

 

0..255 

00. .FF 

0..100 

3) Tilt-
  coarse 

0 .. 300°  

 

0..255 

00..FF 

0..100 

4) Tilt-fine 

High- Pos … High- Pos + 1,2° (16 Bit)   

0..255 

00..F F 

0..100 

5) Color 

Colors adjustable via RGB 

 

0..7 

00..07 

0..2,5 

  (fixed) 

Color 01 - Red 

1)

 

 

8..15 

08..0F 

3..5,5 

 

Color 02 - Amber 

1)

 

 

16..23 

10..17 

6..8,5 

 

Color 03 - Warm Yellow 

1)

 

 

24..31 

18..1F 

9..12,5 

 

Color 04 - Yellow 

1)

 

 

32..39 

20..27  13..15,5 

 

Color 05 - Green 

1)

 

 

40..47 

28..2F  16..18,5 

 

Color 06 - Turquoise 

1)

  

 

48..55 

30..37  19..21,5 

 

Color 07 - Cyan 

1)

 

 

56..63 

38..3F  22..24,5 

 

Color 08 - Blue 

1)

 

 

64..71 

40..47  25..27,5 

 

Color 09 - Lavender 

1)

 

 

72..79 

48..4F  28..30,5 

Содержание Ipression XL

Страница 1: ...Instruction Manual from Software Version 1 09 0 3 Manual Version 1 06 e mail service glp de Internet http www glp de...

Страница 2: ...R R R G G G B B B GLP German Light Products GmbH Manual Version 1 06 from Software Version 1 09 0 3 2 For your notes...

Страница 3: ...1 Mounting on the floor upright 7 2 1 2 Mounting in hanging position Head down 7 2 1 3 Mounting in sideway position 8 2 2 Securing the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9 3 Th...

Страница 4: ...the tilt movement see also 1 1 4 LCD Display Menu data entry 5 Base with various connectors and Camlock mounting system Safety eyelets 1 2 4 5 3 base side 1 10 6 7 8 9 10 base side 2 11 12 13 14 6 DM...

Страница 5: ...ranty 6 Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay attention to possible hot parts of the system 7 Never look di...

Страница 6: ...Installation 2 1 Mounting The I IM MP PR RE ES SS SI IO ON N X XL L is fully operational whether it hangs or is mounted to a wall It can also be operated while standing on the floor Keep a safety dist...

Страница 7: ...k quarter turn fasteners Line up and engage the camlock connectors from the floor stand into the base of the fixture and turn the two fasteners 90 to lock them Do the opposite to release them again On...

Страница 8: ...or one of their agents This mounting bar is fixed via the four camlock quick release connectors Two half couplers or clamps are then used to hang the mounting bar This technique is necessary to cope w...

Страница 9: ...he fixture and the fixtures mounting support Install a safety wire that can hold at least 10 times the weight of the fixture 2 3 Connections 2 3 1 Power Supply 100 240 Volt AC 50 60 Hz earth contact t...

Страница 10: ...l of all system functions Pan Manual control for Pan X movement Speed Movements Speed adjustment for Pan Tilt movements see also item below Pan Tilt Movements Manual control for Pan Tilt movement Spec...

Страница 11: ...lt ON or OFF disconnected from power PAN TILT Silent Mode Reduces maximum speed for Pan Tilt DMX Hold Defines whether the last DMX signal is stored or the lamp is switched OFF in case of signal interr...

Страница 12: ...lution mode see also section 4 White Mode ON OFF Adjustments for white balance are activated Reverse Pan Selects Inverse Pan on or off Reverse Tilt SelectsInverse Tilt on or off Reset RESET all functi...

Страница 13: ...dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast...

Страница 14: ...l is set to a value between DMX 16 31 the white balance is used for the RGB output Since there is no Special DMX channel in the Compress DMX Mode the possibility exists to likewise select these settin...

Страница 15: ...ing random patterns slow fast 48 79 30 4F 19 31 5 Shutter open then down dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56...

Страница 16: ...bow effect synchronously Different I IM MP PR RE ES SS SI IO ON N X XL L can have different start colors but will still execute the rainbow effect synchronously If you choose a color different from th...

Страница 17: ...within the fixture If they do the fixture s light output will be significantly reduced and damages to the fixture may occur Regular cleaning will not only ensure the maximum light output but will als...

Страница 18: ...r supply Power consumption 1200 VA Watt Power Input 100 240 V AC 50 60 Hz auto sensing input Fuse protection Micro fuse 6 3x32 mm T15A Operational Parameters Max Ambient Temperature 45 C 113 F integra...

Страница 19: ...nd Random Strobe Pulse Effects Continuous Dimmer 0 100 DMX Control Standard USITT DMX 512 3 5 pole XLR Pin 3 Pin 2 Ground Pin 1 DMX Addressing starts at the DMX channel 001 Pan Tilt 8 16 Bit Pan movem...

Страница 20: ...ED Class 2M 5 M Maintenance 16 Manual Version 1 Max Power Mode 13 Micro fuse 8 Mode key 9 Mounting 6 Mounting in hanging Position 7 Mounting in sidewise Position 8 Mounting on the Floor 6 N Normal Mod...

Страница 21: ...R R R G G G B B B GLP German Light Products GmbH Manual Version 1 06 from Software Version 1 09 0 3 21...

Отзывы: