background image

 

 

 

GLP 

 German Light Products GmbH 

Field Test Documentation

 

5

 

 

1.1  Safety Instructions  

 

 

The

 

 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

X

X

4

4

X

X

L

L

 

 

is  a  High-Tech  Product.  To  guarantee 

a smooth operation, it is necessary to respect the following rules. 

The  manufacturer  of  this  device  will  not  take  responsibility  for 
damages  through  any  disregard  of  the  information  provided  in 
this manual. Warranty claims also will be voided in the case that 
the fixture housing is opened.  

1.  Before  powering  on  the  fixture,  make  sure  that  the  fixtures  fans  and  air 

inlets are clean and not blocked.  

2.  Ensure that the fixture head can rotate unhindered throughout its complete 

range of pan and tilt movement. A safety distance of at least 0.5 m must be 

maintained  between  the  fixture  and  any  easily  inflammable  material  (e.g. 

decoration material).  

3. 

Attention!

 

Don’t  touch  the  fixture  during  the  operation.  This  can  cause 

injuries and/or damages.  

4. 

The  fixture  doesn’t  contain  any  user  serviceable  parts.  Opening  the 

fixture will void all warranties.

 

5.  It  is  necessary  to  wait  at  least  15  minutes  after  disconnecting  the  mains 

power before handling the fixture.. Pay attention to possible hot parts of the 

fixture.  

 

       

-- Danger of BURNING --

 

6. 

Never  look  directly  into  the  beam  of  light  or  into  one  of  the  LEDs.

 

Never  use  optical  apertures  to  observe  the  beam  of  light. 

LED  Class  2M.

 

You'll risk serious injury of your eyes and in particular of your retina.

 

 

 

Attention:

 LED Class 2M can cause injuries of your eyes even 

without optical instruments in front of them or within a distance 
of less than 0.5m and short exposure time.

 

 

Hence: Avoid direct radiation into your eyes!  

7.  To  ensure  safe  operation,  follow  also  the  Installation  guide  described  in 

chapter  2.  Operating  the 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

X

X

4

4

X

X

L

L

 

 

without  suitable  safety  aids 

like Safety cables or clamps/hooks can increase the risk of an accident and 

must be avoided. 

8.  Repair,  maintenance,  and  installation  work  shall  be  done  by  qualified  or 

GLP certified staff only.  You need to pay attention to the common rules of 

technology that are not explicitly mentioned in this manual.  

9.  Use only original GLP   spare  parts.  Any  structural  modification  of  the 

system will terminate all warranty claims. 

10.  Please keep this instruction manual for future reference.  

Содержание Impression X4 XL

Страница 1: ...Instruction Manual from software version Field Test e mail service glp de Internet http www glp de ...

Страница 2: ...GLP German Light Products GmbH Field Test Documentation 2 Notes ...

Страница 3: ...nging position Head down Head down 9 2 3 Securing the Fixture 9 2 4 Connections 10 2 4 1 Power Supply 10 2 4 2 DMX 10 3 The Menu Field 10 4 DMX Channel Selection DMX Protocol 13 4 1 Normal Mode 26 DMX channels 13 4 2 Compress Mode 14 DMX channels 15 4 3 High Resolution Extended Mode 27 DMX Channels 16 5 Maintaining and Cleaning 18 5 1 Safety regulations 18 5 2 Maintenance and Interval rule of thum...

Страница 4: ...Display Menu data entry 4 Base with various connectors and Camlock mounting system 5 DMX Output 5 pin 6 DMX Output 3 pin 7 Micro fuse 5 x 20mm T12A 8 Power Switch 9 Neutrik Powercon Mains power input 10 Blank panel primed for Ethernet 11 DMX Input 3 pin 12 DMX Input 5 pin 13 2x Safety wire points Note Only connect one cable to the DMX Input Output at the same time ...

Страница 5: ...ait at least 15 minutes after disconnecting the mains power before handling the fixture Pay attention to possible hot parts of the fixture Danger of BURNING 6 Never look directly into the beam of light or into one of the LEDs Never use optical apertures to observe the beam of light LED Class 2M You ll risk serious injury of your eyes and in particular of your retina Attention LED Class 2M can caus...

Страница 6: ...sible problems please adhere to the following requirements Do not expose the front of a fixture to direct sunlight or any other strong light sources For outdoor applications during daylight make sure that the front face of any fixture is either shielded or points away from the sun even when fixtures are not in use Do not modify the front glass or lenses of any fixture These requirements have to be...

Страница 7: ...ntion to the regulations of BGV C1 former VBG 70 and DIN VDE 0711 217 The installation shall be done by qualified staff only For the various mounting positions of the I IM MP PR RE ES SS SI IO ON N X X4 4X XL L standing on the floor sideways or hanging different accessories kits are available Through this a safe and firm installation is assured You ll find dedicated connectors on the bottom side o...

Страница 8: ... please use the dedicated tri legged floor stand supplied with your fixture It is fixed to the base of the fixture with fasteners called Camlock quick release connectors Insert the two fasteners and turn each 90 to lock them Do the opposite to release them again On both sides you ll find eyelets to pull though a fixing strap This allows for additional bracing of the fixture ...

Страница 9: ...read bolts Attention Never use a longer bolt as this may damage the interior of the fixture 2 3 Securing the Fixture Regardless of the mounting method of the I IM MP PR RE ES SS SI IO ON N X X4 4X XL L you ll have to use a stipulated safety wire Attach the safety wire through one of the two holes provided on the base of the fixture and connect it to the primary support structure Pay attention to a...

Страница 10: ...the main menu Afterwards you can navi gate through the menu with the Up Down keys Push the Enter key to get in the next menu level or to confirm your settings Make them and set functions ON OFF with the Up Down keys Confirm and save it with the Enter key the display shows OK Push the Mode key to cancel the entry and go back to the main menu To lock or unlock the keys of the menu field press Mode E...

Страница 11: ... contrast PWM Frequ Adj Changes PMW frequency Pan Offset Calibration for Pan Offset Tilt Offset Calibration for Tilt Offset LED adjust White adjust red Adjust intensity for red channel White adjust blue Adjust intensity for blue channel White adjust green Adjust intensity for green channel Clear EEPROM Erase EEPROM memory Diagnose Diagnose fixture functions DMX Image Set image if DMX off Activates...

Страница 12: ... Shutter White Instantaneous value for White Blue Instantaneous value for Blue Green Instantaneous value for Green Red Instantaneous value for Red Color Wheel Instantaneous value for Color Mixing unit Set DMX Mode Select the desired DMX Mode Compressed Mode Fixture works in Compressed mode see also section 4 unterhalb Normal Mode Fixture works in Normal mode see also section 4 unterhalb High Res M...

Страница 13: ... slow fast 129 223 81 DF 51 88 Random colors slow fast 224 255 E0 FF 89 100 6 Red Color mixing system Red 0 100 0 255 00 FF 0 100 7 Green Color mixing system Green 0 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9 White Color mixing system White 0 100 0 255 00 FF 0 100 10 Shutter Shutter closed 0 15 00 0F 0 5 5 Shutter pulse random slow fast 16 47 10 2F 6 18 5 Fade ...

Страница 14: ...1 100 16 Zoom Wide flood narrow spot 0 255 00 FF 0 100 17 Pattern No pattern 0 2 00 02 0 1 Pre defined patterns 03 253 03 FD 2 99 Activates direct access to LED Lenses 254 255 FE FF 100 18 Pattern Section 1 Direct activation of lenses 1 thru 8 Activation in binary style 0 255 00 FF 0 100 19 Pattern Section 2 Direct activation of lenses 9 thru 16 Activation in binary style 0 255 00 FF 0 100 20 Patt...

Страница 15: ...F 47 49 5 Rainbow Effect Stop 2 128 80 50 Rainbow Effect 3 slow fast 129 223 81 DF 51 88 Rainbow Effect random colors slow fast 224 255 E0 FF 89 100 6 Red Color mixing system Red 0 100 0 255 00 FF 0 100 7 Green Color mixing system Green 0 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9 White Color mixing system White 0 100 0 255 00 FF 0 100 10 Shutter Shutter closed...

Страница 16: ...11 50 6F 32 43 Fade on fade off random patterns slow fast 112 143 70 8F 44 56 Strobe random 5s 0 1s 144 199 90 C7 57 77 Strobe effect slow fast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 255 F0 FF 95 100 14 Dimmer coarse Dimmer 0 100 0 255 0 FF 0 100 15 Dimmer fine Dimmer Low 0 255 0 FF 0 100 16 Zoom Wide flood narrow spot 0 255 00 FF 0 100 17 Special Pattern Block 1 See channel 18 0 3 00 03 ...

Страница 17: ...will execute the rainbow effect synchronously Different I IM MP PR RE ES SS SI IO ON N X X4 4X XL L can have different start colors but will still execute the rainbow effect synchronously If you choose a color different from the ones marked with 1 in the tables above the rainbow start color will be red 2 Rainbow effect Stop will pause this function After resuming the rainbow effect will be continu...

Страница 18: ...e reliably throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recom mended under no circumstances should alcohol or solvents be used 5 1 Safety regulations Pull out the mains power plug Wait min 15 minutes after disconnecting power to allow the fixture to cool down 5 2 Maintenance and Interval rule of thumb The contamination of the fixture depends on the env...

Страница 19: ...ull RGBW High efficient Collimator cluster Shutter Dimmer 8 16 Bit Strobe Effect with variable speed between 1 10 flashes per second Random Strobe Pulse Effects Continuous Dimmer 0 100 Zoom 7 to 50 degree continuous zoom Optical Patterns Several hundred pre defined beam patterns with direct access and manipulation DMX Control Standard USITT DMX 512 3 5 pin XLR Pin 3 Pin 2 Ground Pin 1 Pin 4 5 N C ...

Страница 20: ...GLP German Light Products GmbH Field Test Documentation 20 7 Dimensions PAN movement range 660 ...

Страница 21: ...solution Extended Mode 16 I Instruction Version 1 Internet 1 L LED Class 2M 5 M Maintenance 18 Menu Field 10 Micro fuse 10 Mode key 10 Mounting 7 Mounting in hanging Position 9 Mounting on the Floor 8 N Normal Mode 13 O Optical parts 18 P Pan Movement 19 plano convex lenses 6 Power Supply 10 R RESET 13 15 16 S Safety distance 7 Safety information 6 Safety Instructions 5 Secure the Device 9 sunligh...

Страница 22: ...GLP German Light Products GmbH Field Test Documentation 22 ...

Отзывы: