MEDIUS

  NOTE

: Wire dimming conductors as Class 1

1

4

2

3

6

5

Page: 1 / 2

Make electrical connection between fixture (B) 

and wall power cable (C).

Insert fixture bracket (D) into wall bracket (A) and 

secure it in place with supplied screw (E).

B

A

E

C

D

SIDE VIEW

A

A

F

F

Remove the screws (H) on the joiner and put 

them  in a safe place.

G

SIDE VIEW

A

H

Locate wall bracket position using provided client 

drawing. Install mounting brackets (A) to wall. 

Align with structural stud (need double studs – 

distance between screws is 1.250”) or use metal 

anchors with min. length 1.250”. Flat head Philips 

drive screw, nominal size #10, min. length 1.250”.

Locate wall bracket position using provided client 

drawing. Install mounting brackets (A) to wall. 

Align with structural stud (need double studs – 

distance between screws is 1.250”) or use metal 

anchors with min. length 1.250”. Flat head Philips 

drive screw, nominal size #10, min. length 1.250”.

DIRECT/INDIRECT WALL MOUNT - INSTALLATION INSTRUCTIONS

Remove the top cartridges (F) by pulling them up 

and disconnect the quick connectors (G). Keep the 

cartridges (F) in a safe place.