2.2.2 Mounting in hanging position (Head down) (Head down)
To operate the
I
I
M
M
P
P
R
R
E
E
S
S
S
S
I
I
O
O
N
N
X
X
4
4
X
X
L
L
in a hanging position two omega
brackets can be mounted directly to the bottom of the base using the
four Camlock connectors.
Alternatively two half-couplers (clamps) can be mounted directly to the
bottom side of the fixture using M10x16 mm thread bolts.
Attention: Never use a longer bolt as this may damage the interior
of the fixture.
2.3 Securing the Fixture
Regardless of the mounting method of the
I
I
M
M
P
P
R
R
E
E
S
S
S
S
I
I
O
O
N
N
X
X
4
4
X
X
L
L
you'll have to
use a stipulated safety wire. Attach the safety wire through one of the two holes
provided on the base of the fixture and connect it to the primary support
structure. Pay attention to a safe and proper fastening. The safety cable must
comply with EN 60598-2-17 Section 17.6.6 and be capable of bearing a static
suspended load that is ten times the weight of the fixture and all installed
accessories.
Содержание Impression X4 XL
Страница 1: ...Instruction Manual from software version Field Test e mail service glp de Internet http www glp de ...
Страница 2: ...GLP German Light Products GmbH Field Test Documentation 2 Notes ...
Страница 20: ...GLP German Light Products GmbH Field Test Documentation 20 7 Dimensions PAN movement range 660 ...
Страница 22: ...GLP German Light Products GmbH Field Test Documentation 22 ...