GLP impression rgb 120 rz Скачать руководство пользователя страница 18

 

R

R

R

-

-

-

G

G

G

-

-

-

B

B

B

 

 

GLP 

Š

 German Light Products GmbH 

(Instruction version 1.0) / from software version 1.00/30)

 

18

 

6 Technical 

Specifications

 

 

Power supply 
Power consumption 

350 VA (Watt)  

Power Input 

~100-240 V AC, 50-60 Hz (wide range input)  

Fuse protection 

Micro-fuse 5x20 mm, T5A 

Operational Parameters 
Max. Ambient 
Temperature 

45°C (integrated overheating switch)  

Mounting Position 

Any (see chapter mounting) 

Lighting System - Additive Color mixing 
LED Type 

120x Rebel High-power- LEDs 

Lifetime 

100.000 h 

42x green LEDs, 36x blue LEDs, 42x red LEDs 
Wavelength optimized for maximum presentable color space  

Optical System 

High efficient Collimator cluster 
Fixed optical mount with an angel of reflected beam between 10° - 26° 

Shutter / Dimmer (8/16 Bit) 

Strobe- Effect with variable speed between 1 - 10 flashes per second, Random-Strobe, Pulse-
Effects

 

Continuous Dimmer 0 - 100% 

DMX Control 

Standard USITT DMX-512, 3 pole XLR; [+] = Pin 3    [-] = Pin 2    [Ground] = Pin 1.  
Die DMX- Addressing starts at the DMX channel [001]. 

Pan / Tilt (8/16 Bit) 
Pan- movement 

660° in min. 3,2 seconds (Position Feedback) 

Tilt- movement 

300° in min. 1,5 seconds (Position Feedback) 

Weights and Measures  
Width of the base 

340 mm 

Length of the base 

145 mm 

height (head vertical) 

370 mm 

Weight (net) 

8.0 kg 

 

Содержание impression rgb 120 rz

Страница 1: ...Instruction Manual from software version 1 00 30 Instruction version 1 0 e mail service glp de Internet http www glp de...

Страница 2: ...R R R G G G B B B GLP German Light Products GmbH Instruction version 1 0 from software version 1 00 30 2 Notes...

Страница 3: ...unting on the Floor Upright 7 2 1 2 Mounting in hanging Position Head first 7 2 1 3 Mounting in sidewise Position 8 2 2 Secure the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9 3 The Men...

Страница 4: ...g head actively and passively cooled 2 Arm with various cooling vents 3 LCD Display Menu data entry 4 Base with various connectors and Camlock mounting system 1 2 3 4 5 base side 1 6 base side 2 7 8 9...

Страница 5: ...5 minutes after disconnecting the AC before changing the optical carrier Pay attention to possibly hot parts of the system Danger of BURNING 6 Never look directly into the beam of light or one of the...

Страница 6: ...decoration etc Pay attention to the regulations of BGV C1 former VBG 70 and DIN VDE 0711 217 The installation shall be done by qualified staff only For the various mounting positions of the I IM MP PR...

Страница 7: ...em It is fixed with fasteners called Camlock quick release connectors Turn the two fasteners both 90 to lock them Do the opposite to release them again On both sides you ll find eyelets to pull though...

Страница 8: ...rs Two half couplers clamps are now used to mount the system to a standard truss bar This technique is necessary to cope with the torque which accrues in this mounting position In addition it allows a...

Страница 9: ...ion to a safe and proper fastening Install a safety wire that can hold at least 10 times the weight of the fixture Never use the carrying handles for this purpose 2 3 Connections 2 3 1 Power Supply 10...

Страница 10: ...ol for Pan X movement Speed Movements Speed adjustment for Pan Tilt movements see also item below Pan Tilt Movements Manual control for Pan Tilt movement Special Activate the White or Full Power Mode...

Страница 11: ...sition feedback correction for Pan Tilt movement White Adjust Adjustments for a uniform white color white balance only in white mode Red Input for red adjustments Blue Input for blue adjustments Green...

Страница 12: ...X Protocol Normal Mode 15 DMX channels Channel Function Time and Value DMX HEX 1 PAN coarse 0 660 3 2 s 0 255 00 FF 0 100 2 PAN fine High Pos High Pos 2 6 16 Bit 0 255 00 FF 0 100 3 Tilt coarse 0 300...

Страница 13: ...6 0 2 temperature Continuous color temperature correction between 3200k 7200k Applicable only for White color 5 7 255 07 FF 3 100 12 Special Max Power Mode 4 Max light output without white balance 0 1...

Страница 14: ...OFF the RGB goes for the maximum light output Max Power Mode 5 The continuous color temperature correction is applicable only for the White color i e if this function is selected DMX 006 the I Im mp...

Страница 15: ...0 Hz 200 239 C8 EF 78 94 Shutter open 240 249 F0 F9 95 97 5 RESET Min 3 Sec 250 FA 98 Shutter open 251 255 FB FF 99 100 10 Dimmer Dimmer 0 100 0 255 0 FF 0 100 11 Zoom Spot Flood 10 26 0 255 00 FF 0 1...

Страница 16: ...ose a color different from the once marked with 1 in the tables above the rainbow start color will be red 2 Rainbow effect Stop will pause this function After resuming the rainbow effect will be conti...

Страница 17: ...t output will be significantly reduced or damages can occur Regular cleaning will not only ensure the maximum light output but will also allow the fixture to operate reliably throughout its life A sof...

Страница 18: ...blue LEDs 42x red LEDs Wavelength optimized for maximum presentable color space Optical System High efficient Collimator cluster Fixed optical mount with an angel of reflected beam between 10 26 Shut...

Страница 19: ...Instruction Version 1 Internet 2 L LED Class 2M 6 M Maintenance 18 Max Power Mode 15 Menu Field 11 Micro fuse 10 Mode key 11 Mounting 7 Mounting in hanging Position 8 Mounting in sidewise Position 9...

Страница 20: ...R R R G G G B B B GLP German Light Products GmbH Instruction version 1 0 from software version 1 00 30 20...

Отзывы: