GLP impression rgb 120 rz Скачать руководство пользователя страница 11

 

R

R

R

-

-

-

G

G

G

-

-

-

B

B

B

 

 

GLP 

Š

 German Light Products GmbH 

(Instruction version 1.0) / from software version 1.00/30)

 

11

 

 

 

 

Clear 
EEPROM 

 

Erase EEPROM memory 

 

 

Diagnose 

 

Diagnose functions 

 

 

 

Pos Feed 
Pan Delta 

Internal data and function diagnose 

 

 

 

Anz Ti0-
Int-Err 

Internal data and function diagnose 

 

 

 

PFC 
Voltage 

Show the present PFC voltage 

 

 

 

Pos Feed 
Tilt Delta 

Internal data and function diagnose 

 

 

Temperature 
Arm 

 

 

Indicates the arm temperature 

 

Temperature 
Head 

 

 

Indicates the head temperature 

 

PAN/TILT 
Motor Power

 

 

Switches power for Pan/Tilt ON or OFF 
(disconnected from power) 

 

PAN/TILT 
Silent Mode 

 

 

Reduces maximum speed for Pan/Tilt 

 

DMX Hold 

 

 

Defines whether the last DMX signal is stored or the 
lamp is switched OFF in case of signal interruption 

 

Position 
Feedback 

 

 

Automatically position feedback (correction) for 
Pan/Tilt movement  

 

White 
Adjust 

 

 

Adjustments for a uniform white color (white 
balance); only in white-mode  

 

 

Red 

 

Input for red adjustments  

 

 

Blue 

 

Input for blue adjustments 

 

 

Green 

 

Input for green adjustments 

Å

 D

O

W

N

  -

  U

P

 

Æ

 

 

Set DMX 
Image 

 

 

Stores the Scene currently sent to the unit 

 

DMX input 
Monitor 

 

 

Indicates the presently received DMX signal per DMX 
channel  

 

 

Pan 

 

Instantaneous value for Pan 

 

 

Speed 
Movements 

 

Speed adjustment for Pan/Tilt movements 

Æ

 see 

item below 

 

 

Pan/Tilt 
Movements 

 

Instantaneous value for Pan/Tilt movements 

 

 

Special 

 

Instantaneous value for Special 

 

 

White 
Temperature

 

Adjustment of the color temperature for WHITE 

 

 

Dimmer 

 

Instantaneous value for Dimmer 

 

 

 

Shutter 

 

Instantaneous value for Shutter 

 

 

Blue 

 

Instantaneous value for Blue 

 

 

Green 

 

Instantaneous value for Green 

 

 

Red 

 

Instantaneous value for Red 

 

 

Zoom 

 

Instantaneous value for Zoom 

 

 

Color Wheel 

 

Instantaneous value for Color Mixing unit  

 

 

 

Tilt 

 

Instantaneous value for Tilt movement  

Содержание impression rgb 120 rz

Страница 1: ...Instruction Manual from software version 1 00 30 Instruction version 1 0 e mail service glp de Internet http www glp de...

Страница 2: ...R R R G G G B B B GLP German Light Products GmbH Instruction version 1 0 from software version 1 00 30 2 Notes...

Страница 3: ...unting on the Floor Upright 7 2 1 2 Mounting in hanging Position Head first 7 2 1 3 Mounting in sidewise Position 8 2 2 Secure the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9 3 The Men...

Страница 4: ...g head actively and passively cooled 2 Arm with various cooling vents 3 LCD Display Menu data entry 4 Base with various connectors and Camlock mounting system 1 2 3 4 5 base side 1 6 base side 2 7 8 9...

Страница 5: ...5 minutes after disconnecting the AC before changing the optical carrier Pay attention to possibly hot parts of the system Danger of BURNING 6 Never look directly into the beam of light or one of the...

Страница 6: ...decoration etc Pay attention to the regulations of BGV C1 former VBG 70 and DIN VDE 0711 217 The installation shall be done by qualified staff only For the various mounting positions of the I IM MP PR...

Страница 7: ...em It is fixed with fasteners called Camlock quick release connectors Turn the two fasteners both 90 to lock them Do the opposite to release them again On both sides you ll find eyelets to pull though...

Страница 8: ...rs Two half couplers clamps are now used to mount the system to a standard truss bar This technique is necessary to cope with the torque which accrues in this mounting position In addition it allows a...

Страница 9: ...ion to a safe and proper fastening Install a safety wire that can hold at least 10 times the weight of the fixture Never use the carrying handles for this purpose 2 3 Connections 2 3 1 Power Supply 10...

Страница 10: ...ol for Pan X movement Speed Movements Speed adjustment for Pan Tilt movements see also item below Pan Tilt Movements Manual control for Pan Tilt movement Special Activate the White or Full Power Mode...

Страница 11: ...sition feedback correction for Pan Tilt movement White Adjust Adjustments for a uniform white color white balance only in white mode Red Input for red adjustments Blue Input for blue adjustments Green...

Страница 12: ...X Protocol Normal Mode 15 DMX channels Channel Function Time and Value DMX HEX 1 PAN coarse 0 660 3 2 s 0 255 00 FF 0 100 2 PAN fine High Pos High Pos 2 6 16 Bit 0 255 00 FF 0 100 3 Tilt coarse 0 300...

Страница 13: ...6 0 2 temperature Continuous color temperature correction between 3200k 7200k Applicable only for White color 5 7 255 07 FF 3 100 12 Special Max Power Mode 4 Max light output without white balance 0 1...

Страница 14: ...OFF the RGB goes for the maximum light output Max Power Mode 5 The continuous color temperature correction is applicable only for the White color i e if this function is selected DMX 006 the I Im mp...

Страница 15: ...0 Hz 200 239 C8 EF 78 94 Shutter open 240 249 F0 F9 95 97 5 RESET Min 3 Sec 250 FA 98 Shutter open 251 255 FB FF 99 100 10 Dimmer Dimmer 0 100 0 255 0 FF 0 100 11 Zoom Spot Flood 10 26 0 255 00 FF 0 1...

Страница 16: ...ose a color different from the once marked with 1 in the tables above the rainbow start color will be red 2 Rainbow effect Stop will pause this function After resuming the rainbow effect will be conti...

Страница 17: ...t output will be significantly reduced or damages can occur Regular cleaning will not only ensure the maximum light output but will also allow the fixture to operate reliably throughout its life A sof...