3  The Menu Field  

You’ll find the control board on the side part of the arm. It allows you 

to make all necessary adjustments of the 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

.

.

 With the 

Mode-

key you get into the main menu. Afterwards you can navigate 

through the menu with the 

Up/Down-

keys. Push the 

Enter-

key to get 

in the next menu level or to confirm your settings. Make them and set 
functions 

ON/OFF

 with the 

Up/Down-

keys. Confirm and save it with 

the 

Enter-

key (the display shows 

OK

). Push the 

Mode-

key to cancel 

the entry and go back to the main menu.  

Mode

Down

Enter

Up

 

Å

 MODE - ENTER 

Æ

 

 

Level1 

Level 2 

Level 3 

Level 4 

Remark 

DMX Start 
Address 001 

 

 

 

Define the DMX start address 

Special 

Manual DMX   

 

Manual control of all system functions 

 

 

Pan 

 

Manual control for Pan (X-movement)  

 

 

Speed 
Movements 

 

Speed adjustment for Pan/Tilt movements 

Æ

 see 

also item below 

 

 

Pan/Tilt 
Movements 

 

Manual control for Pan/Tilt movement 

 

 

Special 

 

Activate the White- or Full-Power Mode; see also 
DMX table 

 

 

White 
Temperature

 

Manual control for Color temperature  

 

 

Dimmer 

 

Manual control for Dimmer  

 

 

Shutter 

 

Manual control for Shutter 

 

 

Blue 

 

Manual control for blue 

 

 

Green 

 

Manual control for green 

 

 

Red 

 

Manual control for red 

 

 

Color Wheel 

 

Manual control for the color wheel 

 

 

Zoom 

 

Manual control for zoom 

 

 

Tilt 

 

Manual control for Tilt (Y-movement)  

 

Display 
Contrast 

 

 

Adjustment for the Display contrast  

 

Default Set 

 

 

Resetting all functions to original values 

 

Set Dimmer 
Frequency 

 

 

Changes PMW frequency between 600Hz and 
1200Hz 

 

LED Dimmer 
Version 

 

 

Reads out the current LED dimmer (software) version

 

Impression 
Version 

 

 

Reads out the current CPU software version 

 

Adjust 

Key code 
xxxx 

 

Use the code for entering the calibration menu (for 
authorized persons only)  

 

 

Pan Offset 

 

Calibration for Pan-Offset 

Å

 D

O

W

N

  -

  U

P

 

Æ

 

 

 

Tilt Offset 

 

Calibration for Tilt-Offset 

Содержание impression rgb 120 rz

Страница 1: ...Instruction Manual from software version 1 00 30 Instruction version 1 0 e mail service glp de Internet http www glp de...

Страница 2: ...R R R G G G B B B GLP German Light Products GmbH Instruction version 1 0 from software version 1 00 30 2 Notes...

Страница 3: ...unting on the Floor Upright 7 2 1 2 Mounting in hanging Position Head first 7 2 1 3 Mounting in sidewise Position 8 2 2 Secure the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9 3 The Men...

Страница 4: ...g head actively and passively cooled 2 Arm with various cooling vents 3 LCD Display Menu data entry 4 Base with various connectors and Camlock mounting system 1 2 3 4 5 base side 1 6 base side 2 7 8 9...

Страница 5: ...5 minutes after disconnecting the AC before changing the optical carrier Pay attention to possibly hot parts of the system Danger of BURNING 6 Never look directly into the beam of light or one of the...

Страница 6: ...decoration etc Pay attention to the regulations of BGV C1 former VBG 70 and DIN VDE 0711 217 The installation shall be done by qualified staff only For the various mounting positions of the I IM MP PR...

Страница 7: ...em It is fixed with fasteners called Camlock quick release connectors Turn the two fasteners both 90 to lock them Do the opposite to release them again On both sides you ll find eyelets to pull though...

Страница 8: ...rs Two half couplers clamps are now used to mount the system to a standard truss bar This technique is necessary to cope with the torque which accrues in this mounting position In addition it allows a...

Страница 9: ...ion to a safe and proper fastening Install a safety wire that can hold at least 10 times the weight of the fixture Never use the carrying handles for this purpose 2 3 Connections 2 3 1 Power Supply 10...

Страница 10: ...ol for Pan X movement Speed Movements Speed adjustment for Pan Tilt movements see also item below Pan Tilt Movements Manual control for Pan Tilt movement Special Activate the White or Full Power Mode...

Страница 11: ...sition feedback correction for Pan Tilt movement White Adjust Adjustments for a uniform white color white balance only in white mode Red Input for red adjustments Blue Input for blue adjustments Green...

Страница 12: ...X Protocol Normal Mode 15 DMX channels Channel Function Time and Value DMX HEX 1 PAN coarse 0 660 3 2 s 0 255 00 FF 0 100 2 PAN fine High Pos High Pos 2 6 16 Bit 0 255 00 FF 0 100 3 Tilt coarse 0 300...

Страница 13: ...6 0 2 temperature Continuous color temperature correction between 3200k 7200k Applicable only for White color 5 7 255 07 FF 3 100 12 Special Max Power Mode 4 Max light output without white balance 0 1...

Страница 14: ...OFF the RGB goes for the maximum light output Max Power Mode 5 The continuous color temperature correction is applicable only for the White color i e if this function is selected DMX 006 the I Im mp...

Страница 15: ...0 Hz 200 239 C8 EF 78 94 Shutter open 240 249 F0 F9 95 97 5 RESET Min 3 Sec 250 FA 98 Shutter open 251 255 FB FF 99 100 10 Dimmer Dimmer 0 100 0 255 0 FF 0 100 11 Zoom Spot Flood 10 26 0 255 00 FF 0 1...

Страница 16: ...ose a color different from the once marked with 1 in the tables above the rainbow start color will be red 2 Rainbow effect Stop will pause this function After resuming the rainbow effect will be conti...

Страница 17: ...t output will be significantly reduced or damages can occur Regular cleaning will not only ensure the maximum light output but will also allow the fixture to operate reliably throughout its life A sof...

Страница 18: ...blue LEDs 42x red LEDs Wavelength optimized for maximum presentable color space Optical System High efficient Collimator cluster Fixed optical mount with an angel of reflected beam between 10 26 Shut...

Страница 19: ...Instruction Version 1 Internet 2 L LED Class 2M 6 M Maintenance 18 Max Power Mode 15 Menu Field 11 Micro fuse 10 Mode key 11 Mounting 7 Mounting in hanging Position 8 Mounting in sidewise Position 9...

Страница 20: ...R R R G G G B B B GLP German Light Products GmbH Instruction version 1 0 from software version 1 00 30 20...

Отзывы: