Fusion MBL40 User Manual Rev. A 

 

 

the fixture if a primary attachment fails. The secondary attachment must be approved 
by an official body such as TÜV as a safety attachment for the weight that it secures, it 

must comply with EN 60598-2-17 Section 17.6.6, and it must be able to support a static 
suspended load that is ten times the weight that it secures. 

● 

If the fixture is installed in a location where it may be exposed to forces such as wind 
pressure, vibration or movement, make sure that the installation can withstand these 

forces. Monitor weather forecasts constantly. Take down the installation immediately if 
there is any risk of weather conditions that could destabilize the installation. 

● 

Check that all covers and items of rigging hardware are secure before using the fixture. 
Do not operate the fixture with missing or damaged covers, shields or any optical 
component. 

● 

Restrict access below the work area and work from a stable platform whenever 
installing, servicing or moving the fixture. 

● 

If the fixture becomes damaged, stop using it immediately and disconnect it from 
power. Do not attempt to use a fixture that is obviously damaged. 

● 

Do not modify the fixture in any way not described in its user documentation. 

● 

Install genuine GLP parts only. 

Содержание Fusion MBL40

Страница 1: ...Fusion MBL40 User Manual Software version 1 0...

Страница 2: ...companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information co...

Страница 3: ...Installation 15 Permitted mounting options 15 Securing fixtures with a safety cable 15 Installing on a surface at any angle 16 Installing on a rigging truss or similar structure 16 5 AC mains power 1...

Страница 4: ...X Mode 2 Advanced 30 13 Service 32 Cleaning 32 Installing optional barndoors 32 GLP Service and Support 33 14 Technical specifications 34 Optics 34 Control 34 Installation 34 Electrical 34 Connections...

Страница 5: ...annel Index is a separate guide to the DMX control channel layout and DMX commands available All documents are available for download from www glp de The Fusion MBL40 is intended for use by experience...

Страница 6: ...by the end user Read and follow the user documentation for all additional equipment Electrical safety Do not allow the fixture to become immersed Do not expose the fixture to high pressure water proj...

Страница 7: ...t that a fuse has blown disconnect the fixture from power and send it to a technician authorized by GLP for repair Fire safety and protection from burns Do not operate the fixture if the ambient tempe...

Страница 8: ...meter of anyone working on or near the fixture Installation safety and protection from personal injury Installation must be performed by qualified personnel only and carried out in accordance with all...

Страница 9: ...n withstand these forces Monitor weather forecasts constantly Take down the installation immediately if there is any risk of weather conditions that could destabilize the installation Check that all c...

Страница 10: ...high powered beam lights directly at the fixture Do not operate the fixture in ambient temperatures above 40 C 104 F Allow free airflow around the fixture IP rating MBL40 fixtures are IP65 rated IP s...

Страница 11: ...cable bends only Do not subject connections to bending forces or allow connections to bear the weight of long lengths of cable Avoiding damage from dust and airborne particles Carry out regular visual...

Страница 12: ...www glp de Avoiding damage to the fixture 12 Fusion MBL40 User Manual Rev A GLP Asia 852 3151 7730 GLP Nordic 46 737 57 11 40...

Страница 13: ...temporary installations Its rugged construction and IP65 rating mean that it can also be used outdoors in temporary installations if precautions are taken to prevent immersion in water and damage from...

Страница 14: ...tted 1 Clamping handwheel to adjust tilt of mounting bracket 2 DMX IN THRU 5 pin XLR 3 CCT rotary control knob see Rotary switches in section 8 4 Control panel with LCD display see section 9 5 Dimmer...

Страница 15: ...rements Note the requirement to secure lighting fixtures with safety cables in temporary installations Permitted mounting options An MBL40 fixture may be installed in one of the following ways Fastene...

Страница 16: ...ou will need at least two fasteners Drill holes if necessary 4 Fasten the mounting bracket to the surface by passing at least two suitable fasteners such as grade 8 8 steel bolts or screws through the...

Страница 17: ...ry 2 Line up the fasteners of the Omega bracket with the holes in the mounting bracket of the MBL40 as shown in Figure 3 3 Lock the Omega bracket onto the MBL40 by turning the fasteners through 90 deg...

Страница 18: ...xternal dimmer The MBL40 does not have a power ON OFF switch Power is applied to the fixture as soon as the power cable becomes live The MBL40 has a 3 conductor Neutrik powerCON TRUE1 Mains IN power i...

Страница 19: ...tal to power in one chain at 200 240 V 50 Hz The power input cable supplied with the fixture is rated 16 A maximum Add together the maximum current draw ratings of all the devices that you intend to c...

Страница 20: ...supply DMX data to fixtures Keep connectors sealed with their rubber caps at all times when not in use The MBL40 has two 5 pin XLR connectors for IN and THRU connections to a DMX data link MBL40 fixt...

Страница 21: ...E1 mains power input connector supports hot plugging and connecting and disconnecting a live power cable is an option especially if you need to shut down power urgently but it is still good practice t...

Страница 22: ...dimming range Theatrical is an S shaped curve that gives finer control at low and at high light levels Square Law gives finer control at low light levels and coarser control at high light levels Inver...

Страница 23: ...NUAL menu option when the rotary switches are set to Manual position These settings are available via SETTINGS NO DMX on the fixture s control panel and using the Control Settings DMX channel Display...

Страница 24: ...p After it has booted the panel displays the default screen see Figure 5 The default screen displays the fixture s DMX mode and the DMX address that the fixture is using By default the display will fl...

Страница 25: ...0 MIN OFF Set time for screen to turn off SCRNFLASH ON OFF Set screen to flash when no DMX is present SETTINGS SCRNLOCK 01 MIN 05 MIN 10 MIN OFF Set time for screen to lock TIME CUR 00 00 hh mm Shows...

Страница 26: ...00K W000C000 See note below 5800K W000C000 See note below CCT 6500K W000C000 See note below WW LED 000 Adjust the overall WW level CW LED 000 Adjust the overall CW levels DEF CAL LOAD Hold Enter for 3...

Страница 27: ...elow DMX 60 23 5 no light will be output Mode 1 Standard 1 CCT 2 Master dimmer DMX Mode 2 Advanced provides a selection of fixed color temperatures on the first channel a master dimmer on the second c...

Страница 28: ...DMX control channel layout In the following DMX channel layout tables Default settings are indicated with bold type Where commands are marked with an asterisk you must send that value continuously for...

Страница 29: ...47 1 48 6 5200 125 129 49 0 50 6 5100 130 134 51 0 52 5 5000 135 139 52 9 54 5 4900 140 144 54 9 56 5 4800 145 149 56 9 58 4 4700 150 154 58 8 60 4 4600 155 159 60 8 62 4 4500 160 164 62 7 64 3 4400 1...

Страница 30: ...9 45 1 46 7 5300 120 124 47 1 48 6 5200 125 129 49 0 50 6 5100 130 134 51 0 52 5 5000 135 139 52 9 54 5 4900 140 144 54 9 56 5 4800 145 149 56 9 58 4 4700 150 154 58 8 60 4 4600 155 159 60 8 62 4 4500...

Страница 31: ...6 32 9 Dimmer speed Fast 85 89 33 3 34 9 Dimmer speed Smooth 90 94 35 3 36 9 No function 95 124 37 3 48 6 Dimmer curve Linear 125 129 49 0 50 6 Dimmer curve Theater 130 134 51 0 52 5 Dimmer curve Squa...

Страница 32: ...usehold or automotive glass cleaning product Do not apply pressure to the clear front or display on the back of the fixture as you may scratch these surfaces Installing optional barndoors An optional...

Страница 33: ...a safety bond between one of the holes 3 in the top corner of the barndoors assembly and the main fixture to prevent the barndoors falling if they become detached from the main fixture GLP Service an...

Страница 34: ...tance to combustible materials 0 2 m 8 in Minimum distance to illuminated surfaces 0 2 m 8 in Installation environment Temporary or permanent indoor installation temporary outdoor installation Seconda...

Страница 35: ...l specifications Fusion MBL40 User Manual Rev A 35 Included items Power cable with Neutrik powerCON TRUE1 mains input plug Dimensions and weight Length 482mm 19 ins Width 320 mm 12 6 ins Height 217 mm...

Страница 36: ...www glp de Dimensions 36 Fusion MBL40 User Manual Rev A 15 Dimensions All dimensions are in millimeters 482 320 217 380...

Страница 37: ...Fusion MBL40 User Manual Rev A 37...