German Light Products®
AC mains power
Fusion MBL20 User Manual Rev. A
19
that it has a connection to ground / earth and that it has an integral cable grip. Follow the
cord cap / plug manufacturer’s assembly instructions.
If you need to install a Neutrik powerCON TRUE1 connector on a power cable, follow the
instructions given in the Support area of the Neutrik website at
Live or L
Neutral or N
Ground / Earth or
US system
Black White
Green
EU system
Brown Blue Yellow/green
Connecting multiple fixtures to power in a chain
You can connect fixtures to power in a daisy-chain to simplify your power circuit layout.
MBL20 fixtures have 2.5 mm2 internal wiring from Power IN to Power THRU connectors.
Warning!
Do not connect more than six (6) MBL20 fixtures in total to power in one
chain at 100-120 V, 60 Hz. Do not connect more than twelve (12) MBL20 fixtures
in total to power in one chain at 200-240 V, 50 Hz.
The power input cable supplied with the fixture is rated 16 A maximum. Add
together the maximum current draw ratings of all the devices that you intend to
connect to power in a daisy chain and do not create a chain with a total
maximum current draw of more than 16 A, or you will create a risk of fire and
electric shock.
To connect fixtures to power in a chain:
1. Obtain power relay cables that have male and female Neutrik powerCON TRUE1
connectors. Cables must be minimum 14 AWG or 1.5mm
2
, rated minimum 16 A and
suitable for the environment and application.
2. Connect the power input cable to the Mains IN socket of the first fixture as described
under ‘Connecting to power’ on page 18.
3. Connect a relay cable to the Mains OUT / THRU socket of the first fixture and to the
Mains IN socket of the second fixture.
4. If you are using 100-120 V, 60 Hz AC mains power you can continue connecting MBL20
fixtures Mains OUT / THRU socket to Mains IN socket until the chain contains a maximum
of six (6) fixtures in total. If you are using 200-240 V, 50 Hz AC mains power you can
continue connecting fixtures Mains OUT to Mains IN until the chain contains a maximum
of twelve (12) fixtures total.