background image

 German Light Products®

 

Features

 

 

 

Fusion MBL20 User Manual Rev. A 

 

23 

 

The “Manual” position of each switch selects the settings programmed using the MANUAL 

Æ

 CCT and MANUAL 

Æ

 BRI menu options. This allows you to set custom output levels if none 

of the settings on the switches are suitable. 
Note: The rotary switches are only effective when no DMX signal is received and the 
SETTINGS 

Æ

 NO DMX option is set to MANUAL. If DMX is being received, that will always 

override the settings on the rotary switches. 

Behavior when the fixture is not receiving a DMX signal 

You can set the fixture to react in three different ways if no DMX signal is present (if the 
fixture is being controlled by DMX but the DMX signal stops, or if you apply power to the 
fixture when no DMX signal is present): 

● 

Hold

 sets the fixture to continue obeying the last DMX values it received. If the fixture is 

powered up with no DMX signal, the fixture will remain in black out. This is the default 
setting. 

● 

Blackout

 sets the fixture to black out. 

● 

Manual

 sets the fixture to output the current settings of the rotary switches, or the 

MANUAL menu option when the rotary switches are set to “Manual” position. 

These settings are available via SETTINGS 

Æ

 NO DMX on the fixture’s control panel and 

using the 

Control / Settings

 DMX channel.  

Display 

The illuminated LCD display lets you change fixture settings when power is applied. See 
Chapter 9 for more details. 
Using the 

Control / Settings 

DMX channel or the SETTINGS 

Æ

 SCRNTIME option on the 

fixture’s control panel you can set the display to automatically switch off when no buttons 

are pressed for a time. 
The display will flash when no DMX is being received.  You can turn this feature off using the 
SETTINGS 

Æ

 SCRNFLASH option. 

Fixture information 

The 

Info

 menu in the control panel gives access to items of information from the fixture’s 

sensors and memory. You can check temperature sensor readouts, see total operating 
hours counters, and see software version number, for example. 

Factory defaults 

You can customize fixture settings (DMX mode, Display Sleep time etc.) via DMX or using 
the fixture’s control panel. Custom settings are stored after a power off/on cycle and after 
a reset. 
Using the fixture’s control panel option SERVICE 

Æ

 DEFAULT you can restore the settings to 

the factory defaults. This reloads all the fixture’s factory default settings 

except

 DMX 

address and DMX mode 
 
 

Содержание Fusion MBL20

Страница 1: ...Fusion MBL20 User Manual Software version 1 0...

Страница 2: ...companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information co...

Страница 3: ...Installation 15 Permitted mounting options 15 Securing fixtures with a safety cable 15 Installing on a surface at any angle 16 Installing on a rigging truss or similar structure 17 5 AC mains power 1...

Страница 4: ...X Mode 2 Advanced 31 13 Service 33 Cleaning 33 Installing optional barndoors 33 GLP Service and Support 34 14 Technical specifications 35 Optics 35 Control 35 Installation 35 Electrical 35 Connections...

Страница 5: ...annel Index is a separate guide to the DMX control channel layout and DMX commands available All documents are available for download from www glp de The Fusion MBL20 is intended for use by experience...

Страница 6: ...by the end user Read and follow the user documentation for all additional equipment Electrical safety Do not allow the fixture to become immersed Do not expose the fixture to high pressure water proj...

Страница 7: ...t that a fuse has blown disconnect the fixture from power and send it to a technician authorized by GLP for repair Fire safety and protection from burns Do not operate the fixture if the ambient tempe...

Страница 8: ...meter of anyone working on or near the fixture Installation safety and protection from personal injury Installation must be performed by qualified personnel only and carried out in accordance with all...

Страница 9: ...n withstand these forces Monitor weather forecasts constantly Take down the installation immediately if there is any risk of weather conditions that could destabilize the installation Check that all c...

Страница 10: ...high powered beam lights directly at the fixture Do not operate the fixture in ambient temperatures above 40 C 104 F Allow free airflow around the fixture IP rating MBL20 fixtures are IP65 rated IP s...

Страница 11: ...cable bends only Do not subject connections to bending forces or allow connections to bear the weight of long lengths of cable Avoiding damage from dust and airborne particles Carry out regular visual...

Страница 12: ...www glp de Avoiding damage to the fixture 12 Fusion MBL20 User Manual Rev A GLP Asia 852 3151 7730 GLP Nordic 46 737 57 11 40...

Страница 13: ...temporary installations Its rugged construction and IP65 rating mean that it can also be used outdoors in temporary installations if precautions are taken to prevent immersion in water and damage from...

Страница 14: ...ng handwheel to adjust tilt of mounting bracket 2 DMX IN THRU 5 pin XLR 3 CCT rotary control knob see Rotary switches in section 8 4 Control panel with LCD display see section 9 5 Dimmer level rotary...

Страница 15: ...eets all applicable codes and legal requirements Note the requirement to secure lighting fixtures with safety cables in temporary installations Permitted mounting options An MBL20 fixture may be insta...

Страница 16: ...at the surface is secure and can safely hold the weight of the fixture plus all hardware and cables 2 Loosen the handwheels on the mounting bracket adjust the bracket to a suitable angle and tighten t...

Страница 17: ...pipe you can fasten it to the truss using G clamps If you are going to install the fixture in any other orientation you must use half coupler clamps that completely surround the truss chord or pipe Fi...

Страница 18: ...xternal dimmer The MBL20 does not have a power ON OFF switch Power is applied to the fixture as soon as the power cable becomes live The MBL20 has a 3 conductor Neutrik powerCON TRUE1 Mains IN power i...

Страница 19: ...tal to power in one chain at 200 240 V 50 Hz The power input cable supplied with the fixture is rated 16 A maximum Add together the maximum current draw ratings of all the devices that you intend to c...

Страница 20: ...supply DMX data to fixtures Keep connectors sealed with their rubber caps at all times when not in use The MBL20 has two 5 pin XLR connectors for IN and THRU connections to a DMX data link MBL20 fixt...

Страница 21: ...E1 mains power input connector supports hot plugging and connecting and disconnecting a live power cable is an option especially if you need to shut down power urgently but it is still good practice t...

Страница 22: ...dimming range Theatrical is an S shaped curve that gives finer control at low and at high light levels Square Law gives finer control at low light levels and coarser control at high light levels Inver...

Страница 23: ...NUAL menu option when the rotary switches are set to Manual position These settings are available via SETTINGS NO DMX on the fixture s control panel and using the Control Settings DMX channel Display...

Страница 24: ...own or reduce a number ENTER Activate the control panel if it is in sleep mode Then enter a menu select a setting or implement a command When you apply power to the fixture it boots up After it has bo...

Страница 25: ...display to lock after a period of time to prevent accidental changes to the options using the SETTINGS SCRNLOCK menu setting To unlock hold down the MENU and ENTER buttons together for 3 seconds When...

Страница 26: ...OFF Set time for screen to turn off SCRNFLASH ON OFF Set screen to flash when no DMX is present SETTINGS SCRNLOCK 01 MIN 05 MIN 10 MIN OFF Set time for screen to lock TIME CUR 00 00 hh mm Shows how l...

Страница 27: ...ow 4200K W000C000 See note below 5800K W000C000 See note below CCT 6500K W000C000 See note below WW LED 000 Adjust the overall WW level CW LED 000 Adjust the overall CW levels DEF CAL LOAD Hold Enter...

Страница 28: ...DMX 60 23 5 no light will be output Mode 1 Standard 1 CCT 2 Master dimmer DMX Mode 2 Advanced provides a selection of fixed color temperatures on the first channel a master dimmer on the second channe...

Страница 29: ...9 12 DMX control channel layout In the following DMX channel layout tables Default settings are indicated with bold type Where commands are marked with an asterisk you must send that value continuousl...

Страница 30: ...8 6 5200 125 129 49 0 50 6 5100 130 134 51 0 52 5 5000 135 139 52 9 54 5 4900 140 144 54 9 56 5 4800 145 149 56 9 58 4 4700 150 154 58 8 60 4 4600 155 159 60 8 62 4 4500 160 164 62 7 64 3 4400 165 169...

Страница 31: ...15 119 45 1 46 7 5300 120 124 47 1 48 6 5200 125 129 49 0 50 6 5100 130 134 51 0 52 5 5000 135 139 52 9 54 5 4900 140 144 54 9 56 5 4800 145 149 56 9 58 4 4700 150 154 58 8 60 4 4600 155 159 60 8 62 4...

Страница 32: ...9 Dimmer speed Fast 85 89 33 3 34 9 Dimmer speed Smooth 90 94 35 3 36 9 No function 95 124 37 3 48 6 Dimmer curve Linear 125 129 49 0 50 6 Dimmer curve Theater 130 134 51 0 52 5 Dimmer curve Square La...

Страница 33: ...mpened with a household or automotive glass cleaning product Do not apply pressure to the clear front or display on the back of the fixture as you may scratch these surfaces Installing optional barndo...

Страница 34: ...stall a safety bond between one of the holes 3 in the top corner of the barndoors assembly and the main fixture to prevent the barndoors falling if they become detached from the main fixture GLP Servi...

Страница 35: ...m distance to combustible materials 0 2 m 8 in Minimum distance to illuminated surfaces 0 2 m 8 in Installation environment Temporary or permanent indoor installation temporary outdoor installation Se...

Страница 36: ...cifications 36 Fusion MBL20 User Manual Rev A Included items Power cable with Neutrik powerCON TRUE1 mains input plug Dimensions and weight Length 370mm 14 6 ins Width 250 mm 9 8 ins Height 170 mm 6 7...

Страница 37: ...German Light Products Dimensions Fusion MBL20 User Manual Rev A 37 15 Dimensions All dimensions are in millimeters 370 250 170 270...

Страница 38: ......

Отзывы: