Pan disable / Tilt disable
These options allow you to disable the startup reset movements or disable the drive of
the pan and/or tilt motors. The options are
-
Off
: Normal motor control
-
Reset Disabled
: The fixture will not do its power on reset sequence on this motor but
the motor is still controlled. This can be used when a fixture is mounted in a
confined space and would collide with an obstruction if it did the reset sequence.
-
Current Disabled
: The motor drive function is completely disabled. This is mostly
used for service or diagnostics.
Preset settings and factory defaults
You can store three different versions of option settings using the
Service > Service
Advanced > Save Settings
menu and load them using the
Load Settings > Preset 1-2-3
options. These allow you to quickly set up the fixture in a particular configuration.
Settings are stored after a power off/on cycle and after a reset.
Two options are available in the fixture’s control panel for deleting multiple custom
settings and restoring defaults:
-
Service > Default Settings
reloads all the fixture’s factory default settings
except
DMX address, DMX mode, captured scene, preset settings and offset values. This
option returns the fixture to baseline settings without affecting its basic
configuration in an installation.
-
Service > Service Advanced > Factory Backup
reloads all the fixture’s factory
default settings
including
DMX address, DMX mode, and erases all storage. This
option reinitializes the fixture completely and returns to its state when it left the
factory.
-