www.glp.de
Connecting
to DMX data
20
EXO Wash User Manual Rev. B
6.
Connecting to DMX data
Check that all cables and connectors are suitable for the installation environment and
application (see recommendations in ‘Avoiding damage to the fixture’ on page 10).
Use digital 110 Ohm DMX cable with IP65 5-pin XLR connectors to supply DMX data to
fixtures.
Keep connectors sealed with their rubber caps at all times when not in use.
The EXO Wash 30 has two 5-pin XLR sockets for IN and THRU connections to a DMX
data link.
EXO Wash 30 fixtures support the USITT DMX 512A signal protocol. They also
support RDM (Remote Device Management).
The 5-pin XLR connectors use standard pin allocations:
1 Signal Ground
2 Data –
3 Data +
4 Not used
5 Not used
The DMX cable should start at the console and be daisy-chained through each fixture
to be controlled using the DMX input and DMX link out connectors. If you need to split
the DMX cable, use a powered DMX splitter.
If you would like advice with planning and installing a DMX link, your GLP supplier will
be happy to provide assistance.