Appendix
0020201109_01 Energy Installation and maintenance instructions
29
Setting level
Values
Unit
Description
Default
setting
User-specific
setting
Min.
Max.
d.15
Pump speed, actual value
Current
value
%
PWM percentage for the pump that is requested
by the main PCB.
–
Not adjustable
d.18
Pump operating mode
setting
0
2
–
0 = Discontinuously with burner
1 = Continuously as required by the room ther-
mostat
2 = Permanently
1
Adjustable
d.20
Maximum setting for hot
water target value
50
65
℃
–
60
Adjustable
d.27
Switch from relay 1 to
multi-functional module
1
10
–
Use the accessory's instructions to help you.
1
Adjustable
d.28
Switch from relay 2 to
multi-functional module
1
10
–
Use the accessory's instructions to help you.
2
Adjustable
d.31
Operating mode for the
automatic filling device
0
2
–
0 = Manual
1 = Not active
2 = Automatic
0 or 2
Adjustable
d.34
Fan speed, actual value
Current
value
rpm
Displaying the fan speed
Multiply the displayed value by 100
–
Not adjustable
d.35
Position of 3-way valve
Current
value
–
0 = Heating mode
40 = Mid-position
100 = Hot water handling mode
–
Not adjustable
d.39
Temperature at the hot
water inlet
Current
value
℃
The water temperature that is measured by the
temperature sensor upstream of the mixer valve
is displayed here (if the optional accessory is
installed).
–
Not adjustable
d.40
Heating flow temperature
Current
value
℃
Displaying the heating flow temperature
–
Not adjustable
d.41
Heating return temperat-
ure
Current
value
℃
Displaying the heating return temperature
–
Not adjustable
d.43
Heating curve
0,2
4
K
Note
This code is displayed if an outside temperature
sensor is connected to the product and also only
if no eBUS room thermostat is connected.
Consult the accessory's operating instructions in
order to implement this setting.
1,2
Adjustable
d.45
Base point of the heating
curve
15
25
℃
Note
This code is displayed if an outside temperature
sensor is connected to the product and also only
if no eBUS room thermostat is connected.
Consult the accessory's operating instructions in
order to implement this setting.
20
Adjustable
d.47
Outside temperature
Current
value
℃
Note
This code is displayed if an outside temperature
sensor is connected to the product and also only
if no eBUS room thermostat is connected.
–
Not adjustable
d.62
Night offset
0
30
℃
Selecting the target value reduction between day
(COMFORT period on the room thermostat) and
night (ECO period on the room thermostat)
0
Adjustable
d.67
Remaining burner anti-
cycling time
Current
value
min
Displays the remaining time until the lock ends to
prevent cycles that are too short.
–
Not adjustable
d.71
Maximum heating flow
temperature target value
45
80
℃
–
75
Adjustable
d.85
Minimum output of the
product
–
–
kW
The minimum heating output varies depending
on the product.
–
Adjustable
d.90
Status of the digital eBUS
controller
0
1
–
0 = Not recognised
1 = Recognised
–
Not adjustable
d.94
Delete fault list
0
1
–
Deleting the fault list:
–
0 = No
–
1 = Yes
0
Adjustable