Supplied By www.heating spares.co Tel. 0161 620 6677
22
221100C
8 S e r v i c i n g a n d R e p l a c e m e n t o f P a r t s
2464
WIRED
TAGS
COVER
SWITCH
PHILIPS SES
EDISON SCREW CAPS
2467
Diagram 8.9
Diagram 8.11
Diagram 8.10
Note:
To carry out the work below, first generally follow the
instructions in Section 3.1 and 6.1.
8.8 Insulation
Refer to diagram 6.9 to 6.11 to remove/replace
insulation.
8.9 Glass Base
Refer to diagram 6.6 to remove glass base.
8.10 Underbed Lighting
Note. The bulbs are not covered by the product
guarantee.
Remove the coloured glass panel to gain access, before
replacing a “failed” bulb, check that it is screwed in as
these are Edison Screw bulbs (SES).
See diagram 6.2, 6.3 and 8.9.
8.11 Light Switch
Remove switch cover, pull off wired tags.
Fit and connect new switch, see diagram 8.10.
8.12 Gas Tap Pilot Filter
Gain access to the gas tap as Section 8.7.
The filter, which is very small, is in the pilot port of the
gas tap, to remove use a small non-metallic tool.
When fitting the replacement it is important that the
filter is seated correctly as shown in diagram 8.11.
5525
CIRCLIP
OPERATING
CAM
SECURING
SCREW (2)
PIEZO UNIT
SLOT
PRESSURE
TEST POINT
BODY
FILTER
PLUG
AND PIN
ASSEMBLY
CROSS
SECTION