6.3 Heat Settings
Light the fire front as relevant part of Section 6.1.
See diagram 6.1.
At tap position 1 - centre area only, reduced flame effect.
At tap position 2 - centre area only and flame effect.
At tap position 3 - centre area and partial outer and flame
effect.
At tap position 4 - (Full on) whole area and flame effect.
At tap position 5 - whole area but reduced flame effect.
In the unlikely event of the flame going out whilst the
fire front is on, then turn off. Wait 3 minutes before
relighting.
If relighting for any other reason, wait 2 minutes before
doing so.
6.4 Test for Clearance of Products
Notes
WARNING. Take care. The appliance will get hot
during testing.
To carry out the test on the boiler you will need a smoke
match extension and a torch.
For test, view for spillage each side above fire spigot as
shown in diagram 6.23.
The underbed light will help to make the smoke more
visible.
IN ALL CASES, if spillage continues after the specified
test periods steps must be taken to put the fault(s) right.
Possible causes include, flue obstruction, down draught
or restricted fresh air supply into the room.
If the problem cannot be put right the appliance must be
disconnected and expert advice sought.
6 L i g h t i n g a n d T e s t i n g a n d F i t t i n g I n t e r n a l P a r t s