10 Problems with the device
10.1 Troubleshooting the MULTJET and the Al 1810 CV battery charger
Faults usually occur if the device has not been handled, cared for or maintained properly. The
following table contains the most common faults and remedies to eliminate these faults. If
you have any other problems, please contact your nearest service centre authorised by the
manufacturer, or your nearest authorised specialist dealer.
GB
Fault
Cause
Remedy
Device does not
start
Battery not inserted properly
Battery capacity too low
Faulty battery
Battery overheating, battery status
indicator lights up red
Insert the battery into the holder
until it clicks into place
Charge the battery
Battery defective or at the end of its
life. Replace the battery!
Allow the battery to cool down
No pressure is
built up, or the
pressure varies
Water supply interrupted or filter
blocked
Nozzle or extension blocked
Inlet hose is leaking at the con-
nection, air is being drawn in
Ensure a correct water supply
Clean the filter and the nozzle. Remove
any dirt in the extension.
Replace the connector if necessary
The device is
leaking
Slight leaks with droplets at the con-
nections arise due to the design and
are not a defect
Check the connections and any screw
fittings and tighten them up as required
Status display batt.;
4 displays flash
Overload cutout /
temperature protection
Allow the device and the battery to
cool down for around 5 minutes and
do not use them in that time
Status display batt.;
4 displays flash
Low voltage cutoff
Charge the battery
Water in the
device
Used during rain
Fell into water
Housing damaged
Hold the device vertically so that the
water can run out of the dis-charge
openings (see Fig.
)
Allow the device to dry out for 24 h
Contact the customer service section
20
Battery charging
display continu-
ously lit, charging
is not possible
Battery not inserted properly
Battery contacts dirty
Faulty battery
Insert the batt. correctly into the charger
Clean the battery contacts, e.g. by
plugging in and unplugging the bat-
tery several times, if necessary
Replace the battery
Battery charging
display does not
light up
Mains plug for the charger has not
been plugged in (properly)
Mains outlet, power cable or char-
ger defective
Insert the mains plug (fully) into the
mains outlet
Check the mains voltage. If necessa-
ry, have the charger checked over by
an authorized repair shop for GLORIA
electrical power tools
MULTIJET.qxp_Text_GB 06.01.20 15:50 Seite 31