background image

 

 

REV. 01 2020

 

20 / 28 

 

6.4.5   SPLIT FUNCTION  
 

The SPLIT function is used to position the adhesive weight behind the wheel spokes so that they are 
no longer visible. It is advisable to use this function only in the static unbalance or in the 

ALU

 mode. 

Input the wheel data and start the spin. To start the SPLIT function, in the following data for an 
example: 
 
Fig. 24 

 

At 

ALU

 mode, the unbalanced amount of the 

outer  side  of  the  rim  shown  on  the  digital 
readouts is 30g. 
 
 
 
Press           to SPLIT function. 
 
 
 
Choose the first spoke of two adjacent spokes. 
Rotate  the  wheel  to  move  the  first  spoke  to  12 
o’clock position. 
 
 
 
Press             to memorize the position. 
 
Choose the second spoke of two spokes. 
Rotate  the  wheel  to  move  the  second  spoke  to 
12 o’clock position. 
 
 
Press             to memorize the position. 

 

 

Move  the  first  spoke  back  to  the  memorized 
position.  Brake  the  pedal  and  then  apply  the 
adhesive  weights  on  the  position  according  to 
the  unbalanced  amounts  shown  on  the  digital 
readouts. 

 
 

Move  the  second  spoke  back  to  the  memorized 
position.  Brake  the  pedal  and  then  apply  the 
adhesive  weights  on  the  position  according  to 
the  unbalanced  amounts  shown  on  the  digital 
readouts. 

 

To exit SPLIT function, press           and 
then             .  
               . 

 

Содержание GM - U95 PRO

Страница 1: ...REV 01 2020 1 28 USE AND MAINTENANCE MANUAL WHEEL BALANCER WITH MICRO PROCESSOR GM U95 PRO...

Страница 2: ...roughout this manual the following symbols and printing characters are used to facilitate reading Indicates the operations which need proper care Indicates prohibition Indicates a possibility of dange...

Страница 3: ...1 SPACE REQUIRED 4 2 SHAFTASSEMBLY 4 3 WHEEL GUARD MOUNTING 4 4 ELECTRIC CONNECTION 8 8 9 9 5 CONTROL PANEL AND MENU FUNCTION 10 5 1 DISPLAY PANEL 5 2 CONTROL PANEL 10 11 5 3 MENU FUNCTION 12 6 OPERA...

Страница 4: ...should be taken as correct 1 3 MANUAL KEEPING For a proper use of this manual the following is recommended Keep the manual near the lift in an easily accessible place Keep the manual in an area protec...

Страница 5: ...el under emergency conditions A wheel guard of high impact plastic that is designed to prevent the counterweights from flying out in any directing except toward the floor A switch interlock system pre...

Страница 6: ...body G Foot brake H Wheel weight tray I LED lighter J Control panel K Laser pointer on 6 o clock 2 6 TECHNICAL SPECIFICATION Max wheel weight 75kg Wheel diameter 39 1000mm Rim diameter 10 32 255 810m...

Страница 7: ...SPORTATION UNPACKING AND STORAGE transported in its original packaging shown on the package itself may be moved by means of a fork lift Insert the forks at the points shown cardboard and the nylon bag...

Страница 8: ...on preferably concrete The balancer must sit solidly on its three feet If the balancer is not leveled the balancer will not and may produce inaccurate balance readings elect a location for the balance...

Страница 9: ...mproper electrical hook up can damage motor and will not be covered under warranty The machine is supplied with a single phase mains cable plus earth ground Check to make sure the characteristics of y...

Страница 10: ...position of application for correction weights 3 Digital readouts AMOUNT OF UNBALANCE inside 4 LED indicator POSITION OF UNBALANCE inside 5 Indicator inner adhesive weight position at 6 o clock 6 Indi...

Страница 11: ...signal is enabled pressing of any push button is accompanied by a Beep Fig 8 CONTROL PANEL 1 Unbalance reading selection 2 Unbalance mode selection 3 Function selection UP 4 Rim parameters selection...

Страница 12: ...OPT function DIAMETER mm inch WIDTH mm inch WHEEL GUARD on off Start from GUARD closing Approx 1 5g or 0 1 0 25oz BEEP on off Entry SET UP menu g oz unbalance measurement unit See SELF CALIBRATION cha...

Страница 13: ...ne Performing a spin can be started by pressing START button or closing the wheel guard if START FROM GUARD CLOSING is enabled When the figures have been established the spin is automatically braked t...

Страница 14: ...the inner side of the hub Select the cone that best fits the centre hole in the wheels Slide the cone onto the shaft with the large end towards the faceplate Lift the wheel onto the shaft and centre...

Страница 15: ...alues also can be entered either manually or automatically At special request the machine can be supplied with the automatic B gauge 6 3 2 AUTOMATIC ENTRY OF A D Move the A D gauge to measure the A an...

Страница 16: ...the initial screen press Fig 16 Correction of outer side Correction of inner side 6 4 2 STATIC MODE The static mode is used for motorcycles or narrow wheels when it is not possible to place the count...

Страница 17: ...pointer is actuated to point to 6 o clock adhesive position Fig 19 Balancing of light alloy rims with application of adhesive weights on the rim shoulders Both weight positions are at 6 o clock Balanc...

Страница 18: ...ed with the adhesive weights and then measure the dimensions as shown in the diagram Fig 20 Pay attention to press to memorize A1 dimension which should be measured at first then measure AE dimension...

Страница 19: ...asured at first then measure AE dimension which will be memorized automatically Fig 22 Press After performing the balancing spin manually rotate the wheel to the unbalance position to clip on the weig...

Страница 20: ...se the first spoke of two adjacent spokes Rotate the wheel to move the first spoke to 12 o clock position Press to memorize the position Choose the second spoke of two spokes Rotate the wheel to move...

Страница 21: ...ing the static balance press If the unbalance amount shown on the digital readouts is exceeding 30g the digital readouts display YES OPT In this case start OPT function Mark with chalk reference point...

Страница 22: ...change Press to end SELF DIAGNOSIS CHAPTER 7 SET UP 7 1 SELF DIAGNOSIS Fig 25 Rotate the wheel in direction of rotation the readouts display from 0 to 255 Rotate the wheel in reverse direction of rota...

Страница 23: ...7 2 CALIBRATION To access SELF CALIBRATION menu refer to Fig 8 For the self calibration proceed as follows Fig 26 Weight calibration Distance A gauge calibration Diameter D gauge calibration Width B...

Страница 24: ...t spin under normal condition Rotate the wheel manually to 12 o clock and apply 100g weight on the inner side of the rim Start the second spin After the second spin rotate the wheel manually to 12 o c...

Страница 25: ...ress to memorize To exist press Place the supplied calibration meter on the HIGER PROFILE surface of shaft 0 position and then set the gauge tip into the lower hole of the meter Place the supplied cal...

Страница 26: ...not be held responsible for complaints deriving from the use of spare parts made by other manufacturers or for damage caused by tampering or removal of safety systems 8 2 ORDINARY MAINTENANCE This ba...

Страница 27: ...place 3 Reconnect 4 Check for correct voltage 5 Replace The diameter measured is not correct 1 The gauge is not positioned correctly when measuring 2 The gauge is not calibrated 1 Position the gauge c...

Страница 28: ...ES PF 211 Universal flange Universal flange for wheels with without central hole suitable for any vehicle wheel with 3 4 5 holes 1 Complete flange 2 Holes detector 3 Pre centering cone 4 T hexagonal w...