CONNECTING TANK TO SYSTEM
IF REPLACING A TANK
Remove and discard the protective cap from the pressure
tank’s stainless steel water connection. Connect the
tank cross / tee fitting (3- or 5- way connector for inline
or horizontal pressure tanks) into the pressure tank with
adequate pipe sealant (Teflon™ Tape or pipe dope) on the
male threads. Be cautious to not over-tighten, cross, or
strip threads when connecting fittings.
Once the fitting is securely tightened, be sure that the
threaded holes for your pressure switch and pressure
gauge on the tank connection fitting are in the upward
position. (See vertical tank examples Figures 1.1, 1.2, and
1.3, horizontal tank example Figure 1.4 and inline tank
example Figure 1.5).
With adequate pipe sealant, connect all of the fittings,
valves, pressure switch, pressure gauge and water system
pipe / connection unions to the connection fitting.
EASY AS 1-2-3 INSTALLATION
1
2
3
GWS USA, Bradenton, FL, USA • [email protected] • (833) 261-5461 • www.gwsusa.com • 2020 Rev. 02.25
PRESSURE TANK INSTALLATION
Disconnect or shut off all electric
power to t he water suppl y/pump
system. Shut off the water supply
to the system and remove all water pressure from the
system. Failure to follow these instructions may result
in serious injury, death and/or property damage and will
void product warranty.
A suitable pressure relief valve,
set at a maximum of 100 psi, must
be installed in the system near the
pressure tank (see Fig.1.1)
All piping and electrical components should
be in accordance with prevailing local codes
and standards.
Inspect the installation for water leaks
paying close attention to the connection
between the pressure tank and the system piping.
The pressure tank should be installed in the incoming
water supply line from the pump system and before any
point of user (POU) fixtures. (see Fig. 1.1)
STARTING THE SYSTEM
Before turning on the water supply to the system, open a
water faucet to allow air from the system piping to be purged.
Turn on the power to the water supply and the pump should
turn on, filling the system piping. When the water is flowing
freely from the faucet without air, close the faucet. The pump
will continue to run filling the pressure tank.
With all power turned off to the pump system, drain the old
tank, close all water flow to the tank and disconnect it from
the system. Check all fittings, valves, switches and gauges for
proper working condition and replace as appropriate.
Fig. 1.5 Booster Pump w/ Inline Tank
TYPICAL INSTALLATIONS
Tank
Pressure Switch
Pressure Gauge
To System
Fig. 1.2 With Submersible Pump
Drain
Valve
From
Pump
Submersible Pump
Shut Off / Check Valve
Water Flow
Pressure
Relief
Valve
If you have a jet pump, to prevent damage to the well
system, close or plug the opening during tank
installation where the installation where the vacuum and
air volume controls connect to the pump and/or piping.
Fig. 1.3 With Convertible Jet Pump
Tank
Pump
Pressure Switch
Pressure Gauge
Drain
Pressure
Relief
Valve
Drain
Valve
Shut Off / Check Valve
Water Flow
Pump
Pressure Gauge
Tank
Pressure
Switch
Fig. 1.4 Booster Pump w/ Horizontal Tank
Pressure Relief Valve
Pressure
Switch
To Water Usage /
System
Pump
From
Water Source
Tank
Drain Valve
Содержание PressureWave