CALIBRATION INSTRUCTIONS
Now the scale indicator must be calibrated to the scale base so that the indicator can
properly interpret the information that the base is giving it.
For this you will need 2 accurate weights. If you don‟t have accurate weights, use another
scale and some objects you have in the shop and weigh them. You need one that is more
than 10% of the total capacity. You need another that is more than the first but less than
the total capacity.
Let‟s use an example. You have a 440 lb. total capacity scale. You have a box full of
bolts that by using another scale that you believe to be accurate, weighs 56.6 lbs. You
have a bigger box of bolts that weighs 113.7 lbs. We will use these to calibrate the scale.
Your weights might be completely different than this example and that‟s ok.
Go to section 6 CALIBRATION of the manual. It should be around page 25.
Make sure that the scale platform is empty.
Press and hold the HOLD/SETUP button until you see CONFIG.