412587 www.globalindustrial.com
.
8
.
Press the down arrow until you see CAL. Press TARE to enter the CAL (calibration)
function. It should say CAL.ON. Press TARE again. It will say “Zero”. Press the
down arrow and it will say LINE. We are now ready to perform a linear calibration of the
scale. The scale will calibrate at 0 lb. (CAL.P0), a calibration with a weight of 10% of full
capacity (FS) (CAL.P1) and a calibration with a weight which is more than the CAL.P1
weight but less than FS.
Press TARE and you will briefly see CAL.P0 and then you will see something like 0.00 lb.
You have just told the indicator that the empty platform is equal to 0 lb.
Press the TARE key. You will briefly see CAL.P1 and then you will see a weight appear.
Put your first weight in the center of the scale platform.
As you did above, use the right key to move laterally on the indicator and the up/down keys
to change the numbers. If the scale says kg instead of lb., press and hold the UNIT/DATA
key until you see lb.
Change the weight on the indicator to match the weight that you have out on the scale. (in
the example above, this would be 56.6 lbs.) Once this is done press TARE.
The scale will calculate and then stabilize. You will see End.Y and the Y will be flashing.
Press the down arrow to change this to “No”. Press TARE.
You will briefly see CAL.P2 and then a set of numbers with one flashing. As above, out
the weight in the center of the platform and use the right/left and up/down keys to change
the numbers to correspond to the 2
nd
weight that you have prepared (in the example above
113.7 lb.).
Press TARE. The scale will calculate and stabilize. If everything went well, you will see
CAL.END and the scale will return to normal weighing mode and is ready for daily use.
If at any point you saw CAL.Er, this means that there was an error. Press ZERO/ON/OFF
twice to exit CAL mode and start over. Make sure that your 1st weight is more than 10%
of FS and that the 2
nd
weight is more than the first one but less than 100% of FS.