![Global Industrial 412552 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/global-industrial/412552/412552_user-manual_2232994007.webp)
6
Heavy Duty Pallet Digital Scale
User’s Manual
OPERATING INSTRUCTIONS
Power On
●
Turn on the power by pressing the power button for 2 seconds. Once on, the scale will
flash the voltage and then begin to auto-check and count down from 0-9 sequentially
before entering the weighing mode
Note: Anything on the scale before powering on will automatically be tared out.
Zeroing
●
The zero function is used only when the scale is empty and is not at gross zero due to
material build
up
●
Pressing the ZERO key will reset your scale to
0
●
Depending on what your manual zero range parameter is set to, you can zero out any
number within your set selection, after that you will receive an error and will need to
tare
out the
weight
Unit Selection
●
To switch between measuring units ((kg/g/lb/oz/lb:oz) press the UNITS key
Tare Function
●
The Tare function is used when you only wish to see the current change in weight, not the
entire amount of weight that is on the scale
●
When the indicator is in gross mode (gross light is shown) pressing the TARE key will Tare
the current weight on the scale and enter the net mode (net light shown)
●
For example if you are using a container add the container to the scale, press tare and the
display will show the tare symbol
and reset back to 0
●
Add your product to the scale to weigh without the weight of the container
●
To exit Tare mode press the TARE key again to enter gross mode and you will see the total
weight of the container and the product
Note: If you remove the container the scale will show the minus weight of the container
To use a pre-set tare weight
●
Press and hold the TARE key for 2 seconds
●
Input the tare weight using the arrow keys
●
Press print key to confirm