Global Industrial 412552 Скачать руководство пользователя страница 25

24

Heavy Duty Pallet Digital Scale

User’s Manual

nnnnnnn

1. 

Calibration is no good

2. 

Cables are not connected 

properly

3. 

Load cell is defective

1. 

Ensure scale is leveled

2. 

Check load cell connection

3. 

Check load cell input and output 

resistance

4. 

If the above actions don’t work, try the 

following instructions:

• 

Check if the cable that runs 

from the indicator to the 

junction box is damaged. If it 

is, replace the cable.

• 

Check for any water damage 

inside the junction box. If 

there is, replace the junction 

box

• 

Ensure all wires on all 5 

terminal blocks are not loose. 

Retighten the screws if 

needed.

• 

Recalibrate

5. 

If none of the above actions work, one 

or more load cells may be defective

ERR1

No weight was used during 

calibration or the weight 

used was above the max 

capacity.

Use correct weight within the defined 

range

ERR2

The weight used during 

calibration was below the 

minimum required weight.

The calibration weight minimum is 10% 

of the maximum capacity set in C04.
It is recommended to use 60%-80% of 

the maximum capacity.

ERR3

During calibration, the 

input signal is negative

1. Check all wire connections
2. Check load cell for damages
3. Recalibrate
4. If none of the above actions work, the 

PCB may need to be replaced

ERR4

Signal is unstable during 

calibration

Start calibration after the platform is 

stable

ERR5

EEPROM Error

Replace the PCB

Содержание 412552

Страница 1: ...or contact Customer Service at 1 800 645 2986 Model Floor Scale Size Load Capacity 412552 24 X 24 5 000 x 1 lb 412554 36 X 36 2 500 x 0 5 lb 412556 60 X 60 5 000 x 1 lb 412557 60 X 60 10 000 x 2 lb Mo...

Страница 2: ...e Table of Contents SAFETY PRECAUTIONS 2 PREPARATION SET UP 2 FEATURES 3 SPECIFICATIONS 4 DISPLAY AND KEY DESCRIPTION 5 OPERATING INSTRUCTIONS 6 CALIBRATION PROCEDURE 9 INDICATOR PARAMETER SETTINGS 11...

Страница 3: ...ic agent Electrical Safety Unit must be connected to a GFCI outlet Disconnect power before servicing unit All operators MUST discharge themselves before servicing unit by touching a grounded surface o...

Страница 4: ...d Power saving mode Ability to modify gravity based on different geographical locations RS232 output NTEP approved for 5 000 divisions Technical Parameters Accuracy class 5000 e Resolution Display 30...

Страница 5: ...4 Heavy Duty Pallet Digital Scale User s Manual SPECIFICATIONS FIGURE 1 INDICATOR MEASUREMENTS...

Страница 6: ...f a pallet to weigh only the product on it 2 Clears the tare to see the gross weight pallet product ZERO Zero s the scale PRINT Print data The scale is at zero The scale is stable Gross Shows you are...

Страница 7: ...n measuring units kg g lb oz lb oz press the UNITS key Tare Function The Tare function is used when you only wish to see the current change in weight not the entire amount of weight that is on the sca...

Страница 8: ...d press the ZERO key to stabilize thescale Add the second weight to the scale Once stable press the ACCUM key to add the weight to the accumulated total The screen will show n002 to indicate the secon...

Страница 9: ...0d 20 x division and is stable the indicator will hold that weight on the screen for 3 seconds then go back to general weighing Pressing the hold key is unnecessary holding is done automatically when...

Страница 10: ...ll now show OY 13 Press PRINT to access the C4 channel The display will show 14 Enter in the maximum capacity you want to use for this scale by using UNIT and COUNT to move the cursor left and right a...

Страница 11: ...ne ea ar r C Ca al li ib br ra at ti io on n 1 Press PRINT to continue The display will now show 06 2 Press PRINT to access the C06 channel The display will show 6 0 3 The C6 channel is used to calibr...

Страница 12: ...e for 2 seconds 3 Navigate through the settings C01 to C45 as shown in the table 4 below by using the arrow keys and return keys as labeled under each indicator button 4 Press the PRINT key to enter e...

Страница 13: ...hold for animal weighing averages the weight from a sample of 3 seconds 5 Auto Average hold Average hold without the need to press the hold key Unit Conversion C12 See table 2 Upper Limit Alarm C13 Se...

Страница 14: ...ange cannot be bigger than manual zero range Zero Tracking Time C23 0 turn off zero tracking time 1 1 second 2 2 seconds 3 3 seconds Overload Range C24 00 turn off overload range 01 99d overload range...

Страница 15: ...3 0 turn off relay output 1 turn on relay output function 1 2 turn on relay output function 2 3 Reserved menu Gravity of Calibration Location C36 9 7000 9 9999 Gravity of Destination C37 9 7000 9 9999...

Страница 16: ...s Parameter Settings Units Available C01 3 C12 0 gram only C01 4 C12 0 oz only C01 1 C12 0 kg only C01 1 C12 1 kg lb C01 1 C12 2 kg lb oz C01 1 C12 3 kg lb lb oz oz C01 1 C12 4 kg only C01 2 C12 0 lb...

Страница 17: ...C13 000000 Lower Limit Alarm C14 000000 Inner Code Display C15 Set Date C16 Set Time C17 Communication Setting C18 0 Baud Rate C19 3 9600 Manual Zero Range C20 10 Initial Zero Range C21 10 Zero Tracki...

Страница 18: ...icator Quick Disconnect as shown below FIGURE 2 QUICK DISCONNECT CONNECTION DIAGRAM Hardwire Using Inner Terminal Block Connection Note Make sure you follow all the anti static rules to avoid damage t...

Страница 19: ...onnector is used for different purposes depending on the indicator model Figure 4 shows the pin assignment on the DB9 9 pin connector FIGURE 4 DB9 SERIAL CONNECTOR PINOUT RS232 SERIAL OUTPUT FORMAT Fo...

Страница 20: ...5 6 State A Bits0 1 2 0 1 2 Decimal point position 1 0 0 XXXXXX0 0 1 0 XXXXXXX 1 1 0 XXXXX X 0 0 1 XXXX XX 1 0 1 XXX XXX Bits3 4 Division 0 1 X1 1 0 X2 State B BitsS function Bits0 gross 0 net 1 Bits...

Страница 21: ...et printer Parameters 16 17 30 42 45 all effect your ticket print out Normal weighing ticket printout example Accumulation weighing ticket printout example Date 05 01 2017 Time 11 30 52 n001 15 4lb n0...

Страница 22: ...SCII commands as listed below Command Name Function T Tare Save and clear tare Z Zero Zero gross weight P Print Print the weight R G W N W Read gross weight or net weight C Kg lb Kg lb conversion G G...

Страница 23: ...nual Print to Adhesive Label Printers C18 5 C18 6 Printing formats Date Time Net Tare Gross 05 01 2017 11 30 52 25 6lb 10 3lb 35 9lb Date Time XX XX XX yy mm dd XX XX XX hh mm ss NET TARE GROSS 6 00kg...

Страница 24: ...the Sig and Sig wires connected to the load cell and or the junction box if one is used UUUUUU 1 Overload 2 Cables are not connected properly 3 Load cell is defective 1 Reduce the weight 2 Check load...

Страница 25: ...n the screws if needed Recalibrate 5 If none of the above actions work one or more load cells may be defective ERR1 No weight was used during calibration or the weight used was above the max capacity...

Страница 26: ...ss PRINT key to enter C20 parameter 6 Change the value of C20 on the right to 100 if possible using the up arrowkey If 100 is not available change to 20 7 Press PRINT key to enter your selection 8 The...

Страница 27: ...cking range it is the time allowed for the scale to fall within the zero tracking range tolerance and still qualify to be zero d Overload Range Weight allowance that is out of the set calibrated range...

Отзывы: