User’s Manual
Heavy Duty Pallet Digital Scale
CALIBRATION PROCEDURE
C
CA
ALLIIB
BR
RA
AT
TIIO
ON
N P
PR
RO
OC
CE
ED
DU
UR
RE
E
1.
Turn on the scale by holding ON/OFF
(!)
for 2 seconds.
2.
Press HOLD
r--+
and PRINT
...,.
together to access the setup menu.
3.
If done correctly, the display should now
show
[0
L
4.
Press PRINT
...,.
to access the Cl channel. The display should show
[[
I
#].
5.
Press ZERO
_.
to choose which unit you want to calibrate in (1 = kg, 2 = lb).
6.
Press PRINT
...,.
to set the value. The display will now show
[02.
7.
Press PRINT
...,.
to access the C2 channel. The display should show
[[2
#].
8.
Press ZERO
_.
to change the setting to the decimal places desired (The C2 channel is used
to adjust the decimal point on the scale. A value of 1 means there is one digit behind the
decimal point.)
9.
Press PRINT
...,.
to set the value. The display will now show
[03.
10.
Press PRINT
...,.
to access the C3 channel. The display should show
[[3
#].
11.
Press ZERO
_.
to cycle through the values until the desired graduation appears.
(The C3 channel adjusts the divisions on the scale. A value of 1 selected and C2 set to 1, the
scale will read in 0.1 lb. increments.)
12.
Press PRINT
...,.
to set the value. The display will now show
[OY.
13.
Press PRINT
...,. t
o access the C4 channel. The display will show[######].
14.
Enter in the maximum capacity you want to use for this scale by using UNIT
◄ a
nd COUNT
►
to
move the cursor left and right, and TARE
T
and ZERO
_.
to move the values down and up. (The
C4 channel is used to enter in the max capacity of the scale; Make sure this doesn't exceed the
max capacity of the scale; Max capacity divided by the increment set in CO2 and C03 above
cannot exceed 5000.)
15.
Press PRINT
...,. t
o set the value. The display will now show
[OS.
0].
16.
Press PRINT
...,.
to access the CS channel. The display should show
[[S
17.
The CS channel calibrates zero on the scale. Make sure the scale is empty.
18.
Press ZERO
_.
to change the value to 1.
19.
Press PRINT
...,..
The display will count down from 10-1 while the scale is
calibrating zero. When the display shows 0 the zero calibration is complete.
TToo C
Caalliib
brraattee uussiinngg oonnllyy 11 ccaalliib
brraattiioonn w
weeiigghhtt ((S
Siinnggllee P
Pooiinntt C
Caalliib
brraattiioonn))
20. Press PRINT...,. to continue. The display will now show
[06.
21. Press PRINT...,. to access the C06 channel. The display will show
[[6 0].
22. The C6 channel is used to calibrate the scale with a known weight. Press ZERO _. to
I].
Press PRINT ...... The display will flash
SPAn,
and
set the value of C6 to
[[6
then show [######].