CONNECTORS
Connecting load cells to the indicator
●
The indicator can connect with 6 load cells of 350Ω at most
●
4 wire or 6 wire load cell connections are both okay
●
Please contact us directly if you have other special needs for your application
●
There are two connection methods between the load cell and indicator
Quick Disconnect as shown below:
FIGURE 2: QUICK DISCONNECT CONNECTION DIAGRAM
Hardwire (Using Inner Terminal Block Connection:
Note: Make sure you follow all the anti-static rules to avoid damage to your indicator
●
Excitation voltage: 5V
DC
●
Largest output current: 120 mA
●
Excitation circuit: 5 VDC, 4 wire connection, 6 load cell of 350ohm maximum
●
Open the back cover of the weighing indicator, and insert signal cable to the terminal block
(see figure 3); Make sure the screw on terminal block is fixed tightly
FIGURE 3: INNER TERMINAL BLOCK CONNECTION DIAGRAM