Figure 6:

 

SUB-PANEL - RS-485 Data Loop Connections 

JUNO NET Panel - JUNIOR MINI-REP

NOTES: 

On Main Panel DIL Switches 1 & 2 
should be removed.
On Repeaters and sub-panels DIL 
Switches 1 & 2 should be ON

CON3 on interface connect to CON 
5 on J-NET-CON on Main Panel
or JUNO NET Repeater.

CON3 on interface connects to 
DATA LOOP (CON 3) on JUNIOR 
MINI-REP.

 

CON3

CON3

CON3

2

2

2

2

2

2

2

2

2

2

2

2

JUNIOR MINI-REP

SUB-PANEL

JUNO-NET

RS-485 OUT

RS-485 IN

Tx1 a

Tx1 b

Rx2 a

Rx2 b

Rx1 a

Rx1 b

Tx2 a

Tx2 b

Manufacturers of Fire Detection Equipment

globalfire.pt

INSTALLATION MANUAL 1.0 - 12/2015

JUNIOR MINI-REP

Содержание JUNIOR MINI-REP

Страница 1: ...Manufacturers of Fire Detection Equipment globalfire pt INSTALLATION MANUAL 1 0 12 2015 JUNIOR MINI REP INSTALLATION MANUAL version 1 0 12 2015 JUNIOR MINI REP JUNIOR MINI REPEATER PANEL...

Страница 2: ...l panel Like its big brother the J NET Repeater the JUNIOR MINI REP permits full control of the system from multiple locations Connection to the JUNO NET or JUNIOR is via an RS422 RS485 Fibre Optic or...

Страница 3: ...RS485 NEW Detailed information on how to install these units in a network using either Fiber Optics orTCP IP interfaces is availableintheappropriateinterfaceinstallationmanualandinthepanel sinstallat...

Страница 4: ...ll connections should be performed with all elementsofthefiredetectionsystemunpowered This unit should be located where access to the internal components is not restricted and where the unit is not ex...

Страница 5: ...S KEYPAD CONTROLS DISABLEMENTS FIRE FAULT PRE ALARM TEST DISABLED SYSTEM ON ALARM FAULT SUPPLY FAULT SYSTEM FAULT DELAYS ACTIVE SELECTED DETECTORS SOUNDERS DISABLE AUXILIARY RELAYS SOUNDERS ACTIVATE S...

Страница 6: ...P IP COMMUNICATION Typical cable form one end VIEW FROM TOP NOTE THROUGHOUT THE MANUAL THE PIN ON THE 5 WAY MOLEX INDICATES WHICH PIN IS RED N 1 VIEW FROM FRONT MALE FEMALE Figure 2 JUNIOR MINI REP Ne...

Страница 7: ...ided with each interface 24 V DC Ground 0V Earth Figure 3 JUNIOR MINI REP General Hardware and Connections Layout for RS 422 485 connection J NET INT RS 485 CN3 5 way flat cable CON3 DATA LOOP Manufac...

Страница 8: ...ches 1 2 should be removed On JUNIOR MINI REP interface DIL Switches 1 2 should be ON Interface CON3 should be connected to DATA CON on JUNIOR version 3 panel to MINI REP on JUNIOR V4 and to CON3 or J...

Страница 9: ...CON3 should be connected to DATA CON on JUNIOR version 3 panel to MINI REP on JUNIOR V4 and to CON3 or JUNIOR version 2 main board Figure 5 JUNIOR Panel JUNIOR MINI REP Single RS 485 Data Loop Connec...

Страница 10: ...ON3 on interface connect to CON 5 on J NET CON on Main Panel or JUNO NET Repeater CON3 on interface connects to DATA LOOP CON 3 on JUNIOR MINI REP CON3 CON3 CON3 2 2 2 2 2 2 2 2 2 2 2 2 JUNIOR MINI RE...

Страница 11: ...nel is in ACTIVE mode If the LED is flashing GREEN then the panel is in INSTALLATIONmode FAULTS ALARMFAULT IftheLEDisAMBERitindicatesthatthereisaproblemwithaloopsounderorconventionalsoundercircuit Thi...

Страница 12: ...s ACTIVEDELAYS IftheLEDisAMBERitmeansthatthedelaysareactive QUEUEREVIEW FIRE If there is more than one FIRE pressing this button will display the next FIRE report on the LCD display for 20 seconds Sub...

Страница 13: ...integrityofcablesinter connectingalldataloopinterfaces b Verifythatinterfacesareconnectedtotheirassociatedunitsintherightconnector c Verify that DIL Switches 1 2 are placed on the interfaces associate...

Страница 14: ...LATION MANUAL 1 0 12 2015 JUNIOR MINI REP GLOBAL FIRE EQUIPMENT S A S tio dos Barrab s Armaz m Nave Y Caixa Postal 908 Z 8150 016 S o Br s de Alportel PORTUGAL Tel 351 289 896 560 Sales sales globalfi...

Отзывы: