WARNING:  

Electrical Grounding Instruction 

This appliance is equipped with a grounding type plug for your protection against shock hazard and should 

be plugged directly into a properly grounded receptacle.  Do not cut or remove the grounding prong from 

this plug. 

 

CAUTION: 

Risk of fire and electric shock.  Replace power cord with manufacturer’s cord set only, 
part no/ PC-1. 

 

 
INSTALLATION – Code Compliance 

 

 

Global Cooking Systems ovens must be installed under a ventilation hood.  Installation 

of the exhaust hood must be in accordance with the Standard for Ventilation Control 

and Fire Protection of Commercial Cooking Operations, NFPA 96. 

 

NOTE 

All aspects of the oven installation, including placement, utility connections, and ventilation, must comply 

with all applicable local or national codes.  Those codes supersede the requirements and guidelines 

provided in this manual. 

 

NOTE 

In the USA, the oven installation must comply with local codes.  In the absence of local codes, gas oven 

installations must comply with the National Fuel Gas Code, ANSI Z223.1.  Gas and electric ovens, when 

installed, must be electrically grounded in accordance with local codes or in the absence of local codes, 

with the National Electrical Code (NEC), or ANSI/NFPA70. 

 

NOTE 

In Canada, the oven installation must comply with local codes. In the absence of local codes, gas oven 

installations must comply with the Natural Gas Installation Code, CAN/CGA-B149.1 or the Propane Gas 

Installation Code, CAN/CGA-B149.2 as applicable.  Gas and electric ovens must be electrically grounded 

in accordance with local codes, or in the absence of local codes, with the Canadian Electrical Code      

CSA C22.2 

 

 

 

 

 

7

Содержание 3240-D

Страница 1: ...ATING AND INSTALLATION MANUAL For domestic and standard export ovens 3240 3255 3270 Series Ovens Models 3240 S 3255 S 3270 S 3240 D 3255 D 3270 D 3240 T 3255 T 3270 T is a registered trademark of Glob...

Страница 2: ...nstructions to be followed in the event of a suspected gas leak may be obtained by consulting the local gas supplier If the odor of gas is detected call the gas supplier s emergency phone number immed...

Страница 3: ...ALLATION INSTRUCTIONS 9 a Required Equipment 9 b Assemble Base and Legs 9 13 c Place Oven on Base 14 16 d Final Setup 17 18 II VENTILATION SYSTEM 18 a Requirements 18 b Recommendations 18 19 c Other V...

Страница 4: ...are located in the Global Mod Control Cabinet NOTE 3270 models have two Global Mod Control Cabinet one on either end of the oven f Serial Plate Provides utility and operational specifications that eff...

Страница 5: ...neral Specifications Shipping Weight approx 3240 1000 lbs 3255 1100 lbs 3270 1200 lbs Burner Capacity BTU hr max Natural Gas and Propane LP Gas 3240 100 000 BTU per cavity 3255 160 000 BTU per cavity...

Страница 6: ...lls must also be non flammable Required minimum clearances are listed in the Description section of this Manual WARNING Do not place any type of insulating material in the required clearance spaces su...

Страница 7: ...lation must comply with all applicable local or national codes Those codes supersede the requirements and guidelines provided in this manual NOTE In the USA the oven installation must comply with loca...

Страница 8: ...the connector and the quick disconnect device or its associated piping to limit the appliance movement NOTE The installer must contact local building or fire officials concerning installation restrict...

Страница 9: ...12 lifting pipe Two flat appliance dollies Four 4 2 lengths of 2X10 lumber or equivalent b Assemble the base and legs 1 Remove screws holding outer crate together and remove crating material 2 Place...

Страница 10: ...3 Remove oven base legs casters trim rails rear standoffs Fig 2 3 and hardware package Fig 2 10...

Страница 11: ...Fig 3 Rear standoffs 4 Position legs on floor with the triangular braces down and position trim rails as shown in Fig 4 5 Fig 4 11...

Страница 12: ...Fig 5 5 Place provided flat washer over inside hole of each leg as shown in Fig 6 Fig 6 12...

Страница 13: ...on 8 Position base insulation side up on leg and caster assembly and peel insulation blanket back from each corner to expose pre drilled holes 9 Insert 4 mounting bolts and washers in each corner of t...

Страница 14: ...em aside See Fig 9 Fig 9 2 Using thumbscrews removed in Step 1 reinstall lift adapters Note that the openings in the adapters are marked 3240 3255 or 3270 indicating which opening is to be used Be sur...

Страница 15: ...ipe through the rear openings in the lift adapter Fig 10 Fig 10 4 Engage lifts using pipe adapters and lift oven off of crate base 5 Slide crate base out from under oven 6 Position flat appliance doll...

Страница 16: ...of base assembly 4 Reinsert lift pipe and lifts 5 Lift oven off of dollies 6 Rotate oven to the horizontal position and roll base under oven 7 Lower oven onto base assembly taking care that the flang...

Страница 17: ...sengage the four latches securing the front panel to the oven body Fig 13 2 Firmly grasp the front panel and or the upper edge of the oven window slide the panel toward you and lift away from the oven...

Страница 18: ...supplementary equipment DO NOT mount this equipment directly to the oven MOUNTING SUCH EQUIPMENT ON THE OVEN MAY VOID AGENCY CERTIFICATIONS RESTRICT SERVICE ACCESS LEAD TO INCREASED SERVICE AND MAINTE...

Страница 19: ...locations conditions or problems may require the services of a ventilation engineer or specialist Improper ventilation can inhibit oven performance It is recommended that the ventilation system and d...

Страница 20: ...is the bottom of the three rotary switches When the Fan Switch has been set to the ON position turning the Conveyor Switch to the ON position will turn the Conveyor Drive Motor on and activate the LE...

Страница 21: ...the belt speed by pressing the up or down arrow on the Conveyor Speed Controllers keypad 10 The actual oven temperature will rise to the setpoint temperature selected on the Temperature Controller an...

Страница 22: ...nline gas shutoff valve in the CLOSED position disconnect the gas supply and unlock the front casters before moving the oven When all cleaning and servicing is complete 1 If the oven has been moved re...

Страница 23: ...t I MAINTENANCE DAILY a Make sure the oven is cool and the power has been disconnected as described in the warning at the beginning of this section b Clean ALL of the fan inlet screens with a stiff ny...

Страница 24: ...ion code on it using a Magic Marker or equivalent to aid the operator in correct reassembly Example of markings Top Row T1 T2 T3 T4 Bottom Row B1 B2 B3 B4 k Disassemble the air fingers As each finger...

Страница 25: ...ve Conveyor Drive Chain s from the sprocket s iv Remove the master links from the belt s v Remove the belt s from the conveyor s vi The belts should then be rolled and allowed to soak in a detergent s...