4.3. Motor Parameters
Note
: These parameters are preset at the factory and do not normally need to be
changed.
From the Setup menu drop down, open the Induction Motor Vector Control dialog box
as seen below.
Motor Parameters Section;
In the working column verify the Stator Resistance (phase to phase) and
the Stator Inductance are correct and match the motor to be used. The Nominal DC
Bus is preset to 325VDC.
Motor Safety Limits;
Verify that the value is same as motor rating.
Vector Control Parameters;
Verify that the parameters are correct and match the motor to be used.
If new parameters are entered, check that your parameters are correct and push the
Send to Amp button (make sure to disable the amp, otherwise amplifier will prohibit
new parameters to be sent). The parameters in the working column will appear in the
Amp column, next push the Enable Amp button, then the Done button. Close the box.
11
Содержание SMB9675-1A-1
Страница 2: ......
Страница 11: ...Before and after photos of a typical installation 9...
Страница 29: ...27 Fadal is a trademark of Fadal Machining Centers we have no affiliation with Fadal or Mag IAS...
Страница 30: ...28...
Страница 31: ...29...
Страница 35: ......