Service Command Error Codes
When a service command fails the following error codes will be returned:
Error Code
Cause
4
Invalid Argument
15
The amplifier is enabled but command can only be executed when
the amplifier is disabled
16
The amplifier is disabled but command can only be executed when
the amplifier is enabled
17
Attempt to write to a read-only parameter
Monitor Tables
This section contains all entries in the node monitor table.
This table is exposed to the Motion-application programming
interface (MPI). (Direct commands (Monitor_X_Table)
0x0F, 0x011, 0x013 per page 34)
Notes:
¹
Interpolator option Only.
²
Interpolator mode must be setup & cal to monitor these
channels. Sine and Cosine data are after user set gain and
offsets.
Monitor_
X
Data (16-bit)
0
R phase current
1
S phase current
2
T phase current
3
reserved
4
R demand voltage
5
S demand voltage
6
T demand voltage
7
Measured Bus voltage
8
reserved
9
reserved
10
measured current, 3 phase rectified
=max(abs(Ir), abs(Is), abs(It))
11
measured velocity
12
reserved
13
reserved
14
motor shaft position (bits 15..0)
15
motor shaft position (bits 32..16)
16
Demand A loopback
17
Demand B loopback
18
Interpolator/DBN Status
1
19
Interpolator Sine
1,2
20
Interpolator Cosine
1
,
2