451905.66.07 · FD 9912
EN-13
DHW 300VD+
English
Days
Su
... Mo
Mo - Fr
Sa - Su
Mo - Su
Sets the weekday / block of days on which the lower should be acti-
vated
lower 2
start
00:00
... 23:59
Sets the start time for lowering the domestic hot water set temper-
ature
end
00:00
... 23:59
Sets the end time for lowering the domestic hot water set tempera-
ture
Days
Su
... Mo
Mo - Fr
Sa - Su
Mo - Su
Sets the weekday / block of days on which the lower should be acti-
vated
ventilation 1
start
00:00
... 23:59
end
00:00
... 23:59
Days
Su
... Mo
Mo - Fr
Mo - Su
Sa - Su
Sets the weekday / block of days on which the exhaust air function
should be activated.
Level
0* /
1
/ 2 / 3 / Auto
Setting the desired fan level for the exhaust air function.
ventilation 2
start
00:00
... 23:59
end
00:00
... 23:59
Days
Su
... Mo
Mo - Fr
Mo - Su
Sa - Su
Sets the weekday / block of days on which the exhaust air function
should be activated.
Level
0* /
1
/ 2 / 3 / Auto
Setting the desired fan level for the exhaust air function.
ventilation 3
start
00:00
... 23:59
end
00:00
... 23:59
Days
Su
... Mo
Mo - Fr
Mo - Su
Sa - Su
Sets the weekday / block of days on which the exhaust air function
should be activated.
Level
0* /
1
/ 2 / 3 / Auto
Setting the desired fan level for the exhaust air function.
ventilation 4
start
00:00
... 23:59
end
00:00
... 23:59
Days
Su
... Mo
Mo - Fr
Mo - Su
Sa - Su
Sets the weekday / block of days on which the exhaust air function
should be activated.
Level
0* /
1
/ 2 / 3 / Auto
Setting the desired fan level for the exhaust air function.
Silent 1
start
00:00
... 23:59
end
00:00
... 23:59
Days
Su
... Mo
Mo - Fr
Mo - Su
Sa - Su
Setting which weekday or block of days the Silent function should
be activated with reduced volume flow during heat pump opera-
tion.
vacation
until time
00:00
... 23:59
Date setting for the end of the vacation mode. Active as soon as the
setting is made. Device goes in to stand-by / frost protection
until day
01/01/2017
(only visible for devices with additional heat exchanger and OFF or Sol selected)
solar
Selection
off
bivalent
Sol
Choice of additional heat source
off: (no add. heat source)
Bivalent: 2nd heat generator, e.g. oil, gas or wood boiler
Sol: Thermal solar energy system
switch on difference
6 K ...
8 K
... 10 K
Sets the temperature difference between the collector and cylinder
temperature at which the solar pump should be switched on
Menu block
Menu item
Parameter
Value
Description