5) GAS CONNECTION

The gas connection is located in the rear and on the
underside of the appliance 118 mm (for EF/60),
165 mm (for E/70), 255 mm (for EF/90) from the right
hand side.
There are two ways to carry out the connection to the
main gas line:

A.

The hotplate can be connected with rigid pipe as

specified in AS5601 table 3.1.

B.

The hotplate can be connected with a Flexible

Hose,which complies with AS/ANZ 1869 (AGA
Approved), 10mm ID, class B or D, no more than
1.2m long and in accordance with AS5601.
Ensure that the Hose does not contact the hot
surfaces of the hotplate, oven, dishwasher or other
appliance that may be installed underneath or next to
the hotplate. The Hose should not be subjected to
abrasion, kinking or permanent deformation and
should be able to be inspected along its entire length.
Unions compatible with the hose fittings must be
used and connections tested for gas leaks.
Ensure the supply connection point is accessible with
the appliance installed.
Warning: Ensure that the hose assembly is
restrained from accidental contact with the flue or
flue outlet of an underbench oven.

Natural Gas

Natural Gas installations require the connection of a
gas regulator at the appliance. This regulator is
supplied with the appliance on purchase.
Assemble the regulator (noting the gas flow
direction) and transition pieces (supplied with the
appliance), in accordance with figure 11.
The transition piece on the supply side of the
regulator must be provided by the installer.

Liquified Petroleum Gas

In a U-LPG installation the gas regulation is made
at the gas cylinder and regulation at the appliance
is not required. To connect supply to the appliance
use transition pieces as shown in figure 12. These
pieces are supplied with the appliance on purchase.

WARNING:
THE BURNER FLAME MUST BE ADJUSTED BY
THE INSTALLER.
FAULTY

INSTALLATION

WILL

NOT

BE

COVERED UNDER WARRANTY.
THE APPLIANCE IS FACTORY SET FOR NATURAL
GAS. THE TEST POINT PRESSURE SHOULD BE
ADJUSTED TO 1.00kPa WITH THE WOK BURNER
OPERATING AT MAXIMUM.

9

INSTALLATION

FIG. 11

FIG. 12

Содержание 900GC - AU SS

Страница 1: ......

Страница 2: ...rsons or property caused by incorrect installation or use of the appliance The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors...

Страница 3: ...an support for central ultra rapid burner 6 Cast iron pan support 2F right 7 Cast iron pan support 2F left 8 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 3 control knob front and rear...

Страница 4: ...hen the pan comes to the boil set the knob to the reduced rate position small flame fig 1 Always place a lid on the pans Use only pan with a flat bottom and in thick metal Burners Power ratings Pan in...

Страница 5: ...iance may require additional ventilation This can be achieved by opening a window or by increasing the power of the mechanical exhausting system if installed Abnormal Operation Any of the following ar...

Страница 6: ...s the side edge of the hot plate Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MA...

Страница 7: ...within 450mm above the top of the burner A minimum depth of 60mm from the top of the worktop surface must be provided for the appliance 3 INSTALLING THE HOT PLATE Check that the appliance is in a goo...

Страница 8: ...base can be touched a barrier must be installed to prevent accidental contact with the base This barrier shield must be at least 60 mm below the surface of the working top fig 7 Timber or other suita...

Страница 9: ...oint is accessible with the appliance installed Warning Ensure that the hose assembly is restrained from accidental contact with the flue or flue outlet of an underbench oven Natural Gas Natural Gas i...

Страница 10: ...he appliance is correctly rated to the supply Connect appliance by way of a switched power point THE APPLIANCE MUST BE EARTHED Ensure that this power point is properly earthed Look at the connection w...

Страница 11: ...ied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after all checks have been carried out refer to the authorised servic...

Страница 12: ...oint inlet fitting from the appliance 6 Fit the Natural Gas Regulator supplied in the conversion kit 7 Connect the gas supply to the Regulator 8 Check for gas leaks Do not use a naked flame to check f...

Страница 13: ...ise 4 Shut off gas supply to the appliance 5 Disconnect gas inlet pipe from the Natural Gas Regulator 6 Remove the Natural Gas Regulator from the appliance 7 Fit the U LPG test point inlet fitting sup...

Страница 14: ...TURAL 1 00 1 76 15 0 U LPG 2 75 0 91 10 8 NATURAL 1 00 1 55 12 0 U LPG 2 75 0 70 6 3 NATURAL 1 00 1 20 7 3 BURNERS N DESCRIPTION GAS NORMAL PRESSURE INJECTOR DIAMETER NOMINAL HEAT INPUT MJ h kPa 1 100...

Страница 15: ...g 19 It is advisable to change seal D each time a tap is changed in order to ensure a perfect tightness Greasing the taps see fig 20 21 If a tap becomes stiff to operate it must be immediately greased...

Страница 16: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 22 and comply with the recommendations give...

Страница 17: ...17 TECHNICAL ASSISTANCE AND SPARE PARTS...

Страница 18: ...ce of purchase Important note Service work is to be conducted by authorised persons only It is also adviseable that your cooker is checked regularly and maintained in good condition An annual maintena...

Страница 19: ...out extended warranty please fill in the details on the leaflet and post this off to Glen Dimplex Australia Unit 2 205 Abbotts Road Dandenong South Victoria 3175 Australia If your appliance is covered...

Страница 20: ...20...

Отзывы: