Glen Dimplex 900GC - AU SS Скачать руководство пользователя страница 6

6

CLEANING

IMPORTANT:
Always disconnect the appliance from the gas and electricity mains before carrying out any cleaning
operation.

2) HOT PLATE

Periodically wash the hot plate, the enamelled steel pan support, the enamelled burner caps “C” and the
burner heads “T” (see fig. 6) with lukewarm soapy water. Following this, all parts should be thoroughly rinsed
and dried. Never wash them while they are still warm and never use abrasive powders. Do not allow vinegar,
coffee, milk, salted water, lemon or tomato juice from remaining in contact with the enamelled surfaces for long
periods of time.

WARNINGS:
Comply with the following instructions, before remounting the parts:
- Check that burner head slots “T” (fig. 6) have not become clogged by foreign bodies.
- Check that enamelled burner cap “C” (fig. 6) have correctly positioned on the burner head. It must be

steady.

- The exact position of the pan support is established by the rounded corners, which should be set

towards the side edge of the hot plate.

- Do not force the taps if they are difficult to open or close. Contact the technical assistance service for

repairs.

- Don’t use steam jets for cleaning the cooktop.

CARE & MAINTENANCE

To optimise the appearance and up keep of stainless steel:
1) ALWAYS keep stainless steel out of contact from acid/acid based solvent (liquid or vapour form).
2) After installation, wipe clean all stainless steel products with a soft damp cloth to remove any traces of dirt

(e.g. cement dust) or condensation marks.

In the event where persistent marks appear:

Immediately clean affected areas with stainless steel cleaner, using a clean damp soft cloth.
Ensure surface is rinsed and thoroughly clean of all marks and stainless steel cleaner.

PREVENTATIVE MAINTENANCE

This cooktop should not require ongoing maintenance provided you ensure:
- All spillages are cleaned up as soon as they occur.
- Burners are kept clean.
- Burner ports are free of debris, food or anything else that may cause an obstruction.
- Electrode and thermocouples are kept clean.
- Burners are re-assembled correctly.
- Do not get water in the area where the injectors are located.

FIG. 6

Содержание 900GC - AU SS

Страница 1: ......

Страница 2: ...rsons or property caused by incorrect installation or use of the appliance The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors...

Страница 3: ...an support for central ultra rapid burner 6 Cast iron pan support 2F right 7 Cast iron pan support 2F left 8 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 3 control knob front and rear...

Страница 4: ...hen the pan comes to the boil set the knob to the reduced rate position small flame fig 1 Always place a lid on the pans Use only pan with a flat bottom and in thick metal Burners Power ratings Pan in...

Страница 5: ...iance may require additional ventilation This can be achieved by opening a window or by increasing the power of the mechanical exhausting system if installed Abnormal Operation Any of the following ar...

Страница 6: ...s the side edge of the hot plate Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MA...

Страница 7: ...within 450mm above the top of the burner A minimum depth of 60mm from the top of the worktop surface must be provided for the appliance 3 INSTALLING THE HOT PLATE Check that the appliance is in a goo...

Страница 8: ...base can be touched a barrier must be installed to prevent accidental contact with the base This barrier shield must be at least 60 mm below the surface of the working top fig 7 Timber or other suita...

Страница 9: ...oint is accessible with the appliance installed Warning Ensure that the hose assembly is restrained from accidental contact with the flue or flue outlet of an underbench oven Natural Gas Natural Gas i...

Страница 10: ...he appliance is correctly rated to the supply Connect appliance by way of a switched power point THE APPLIANCE MUST BE EARTHED Ensure that this power point is properly earthed Look at the connection w...

Страница 11: ...ied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after all checks have been carried out refer to the authorised servic...

Страница 12: ...oint inlet fitting from the appliance 6 Fit the Natural Gas Regulator supplied in the conversion kit 7 Connect the gas supply to the Regulator 8 Check for gas leaks Do not use a naked flame to check f...

Страница 13: ...ise 4 Shut off gas supply to the appliance 5 Disconnect gas inlet pipe from the Natural Gas Regulator 6 Remove the Natural Gas Regulator from the appliance 7 Fit the U LPG test point inlet fitting sup...

Страница 14: ...TURAL 1 00 1 76 15 0 U LPG 2 75 0 91 10 8 NATURAL 1 00 1 55 12 0 U LPG 2 75 0 70 6 3 NATURAL 1 00 1 20 7 3 BURNERS N DESCRIPTION GAS NORMAL PRESSURE INJECTOR DIAMETER NOMINAL HEAT INPUT MJ h kPa 1 100...

Страница 15: ...g 19 It is advisable to change seal D each time a tap is changed in order to ensure a perfect tightness Greasing the taps see fig 20 21 If a tap becomes stiff to operate it must be immediately greased...

Страница 16: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 22 and comply with the recommendations give...

Страница 17: ...17 TECHNICAL ASSISTANCE AND SPARE PARTS...

Страница 18: ...ce of purchase Important note Service work is to be conducted by authorised persons only It is also adviseable that your cooker is checked regularly and maintained in good condition An annual maintena...

Страница 19: ...out extended warranty please fill in the details on the leaflet and post this off to Glen Dimplex Australia Unit 2 205 Abbotts Road Dandenong South Victoria 3175 Australia If your appliance is covered...

Страница 20: ...20...

Отзывы: