TECHNICAL

INFORMATION

FOR

INSTALLATION PERSONNEL

This appliance shall be installed only by authorised
persons and in accordance with the manufacturer's
installation instructions, local gas fitting regulations,
municipal building codes, electrical wiring
regulations, AS 5601/AG 601 - Gas Installations and
any other statutory regulations.
The wall and bench surfaces must be capable of
sustaining temperatures of 75 degrees Celsius.
All laminates, fixing adhesive and surfacing materials
should be certified suitable for this temperature.

Any adjoining wall surface situated within 200mm from the
edge of any hob burner must be a suitable non-
combustible material for a height of 150mm for the entire
length of the hob. Any combustible construction above the
hotplate must be at least 650mm above the top of the
burner and no construction shall be within 450mm above
the top of the burner. A minimum depth of 60mm from the
top of the worktop surface must be provided for the
appliance.

3) INSTALLING THE HOT PLATE

Check that the appliance is in a good condition after
having removed the outer packaging and internal
wrappings from around the various loose parts. In case of
doubt, do not use the appliance and contact qualified
personnel.

Never leave the packaging materials (cardboard,
bags, polystyrene foam, nails, etc.) within children’s
reach since they could become potential sources of
danger.

The measurements of the opening made in the top of the
modular cabinet and into which the hot plate will be installed are
indicated in fig. 7.
Always comply with the measurements given for the hole into
wich the appliance will be recessed (see fig. 7 and 8).

The appliance belongs to class 3 and is therefore subject
to all the provisions established by the provisions
governing such appliances.

INSTALLATION

A

B

C

D

E

COMPLY WITH THE DIMENSIONS

Overall Dimensions 5F: 860 x 500 mm

FIG. 7

5F (860)

833

475

120

62.5

90 min.

FIG. 8

7

Содержание 900GC - AU SS

Страница 1: ......

Страница 2: ...rsons or property caused by incorrect installation or use of the appliance The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors...

Страница 3: ...an support for central ultra rapid burner 6 Cast iron pan support 2F right 7 Cast iron pan support 2F left 8 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 3 control knob front and rear...

Страница 4: ...hen the pan comes to the boil set the knob to the reduced rate position small flame fig 1 Always place a lid on the pans Use only pan with a flat bottom and in thick metal Burners Power ratings Pan in...

Страница 5: ...iance may require additional ventilation This can be achieved by opening a window or by increasing the power of the mechanical exhausting system if installed Abnormal Operation Any of the following ar...

Страница 6: ...s the side edge of the hot plate Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MA...

Страница 7: ...within 450mm above the top of the burner A minimum depth of 60mm from the top of the worktop surface must be provided for the appliance 3 INSTALLING THE HOT PLATE Check that the appliance is in a goo...

Страница 8: ...base can be touched a barrier must be installed to prevent accidental contact with the base This barrier shield must be at least 60 mm below the surface of the working top fig 7 Timber or other suita...

Страница 9: ...oint is accessible with the appliance installed Warning Ensure that the hose assembly is restrained from accidental contact with the flue or flue outlet of an underbench oven Natural Gas Natural Gas i...

Страница 10: ...he appliance is correctly rated to the supply Connect appliance by way of a switched power point THE APPLIANCE MUST BE EARTHED Ensure that this power point is properly earthed Look at the connection w...

Страница 11: ...ied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after all checks have been carried out refer to the authorised servic...

Страница 12: ...oint inlet fitting from the appliance 6 Fit the Natural Gas Regulator supplied in the conversion kit 7 Connect the gas supply to the Regulator 8 Check for gas leaks Do not use a naked flame to check f...

Страница 13: ...ise 4 Shut off gas supply to the appliance 5 Disconnect gas inlet pipe from the Natural Gas Regulator 6 Remove the Natural Gas Regulator from the appliance 7 Fit the U LPG test point inlet fitting sup...

Страница 14: ...TURAL 1 00 1 76 15 0 U LPG 2 75 0 91 10 8 NATURAL 1 00 1 55 12 0 U LPG 2 75 0 70 6 3 NATURAL 1 00 1 20 7 3 BURNERS N DESCRIPTION GAS NORMAL PRESSURE INJECTOR DIAMETER NOMINAL HEAT INPUT MJ h kPa 1 100...

Страница 15: ...g 19 It is advisable to change seal D each time a tap is changed in order to ensure a perfect tightness Greasing the taps see fig 20 21 If a tap becomes stiff to operate it must be immediately greased...

Страница 16: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 22 and comply with the recommendations give...

Страница 17: ...17 TECHNICAL ASSISTANCE AND SPARE PARTS...

Страница 18: ...ce of purchase Important note Service work is to be conducted by authorised persons only It is also adviseable that your cooker is checked regularly and maintained in good condition An annual maintena...

Страница 19: ...out extended warranty please fill in the details on the leaflet and post this off to Glen Dimplex Australia Unit 2 205 Abbotts Road Dandenong South Victoria 3175 Australia If your appliance is covered...

Страница 20: ...20...

Отзывы: