Page 6

SYSTEm DESIgN

COLD AND HOT WATER DISTRIBUTION DESIgN - ALL mODELS

Torrent  models  are  designed  to  be  fed  directly  from  mains.   They  fulfill  the 
requirements of Water Byelaw 91, and therefore 

do not require a check valve

 to be 

fitted to the supply pipe.  The performance of the Torrent is directly related to the 
adequacy of the cold supply to the dwelling.  This must be capable of providing for 
those services which could be required simultaneously and the maximum demand 
should be calculated.  Torrent will operate at dynamic pressures as low as 1.5 bar (at 
the appliance) which must be available when local demand is at its maximum, but 
the preferred range is between  and 3.5 bar.

As a general guideline, although a 15mm external service may be sufficient for the 
smaller  dwelling  with  one  bathroom,  a mm  service  is  preferred  (5mm  MDPE) 
and should be the minimum for larger dwellings.

If a water meter is fitted in the service pipe, it should have a nominal rating to match 
the anticipated maximum simultaneous hot and cold water demand, calculated in 
accordance with BS 6700.  This could be 50 litres per minute in some properties.

If the incoming static mains water pressure exceeds 3.5 bar at any point in the 4 
hour cycle then a pressure limiting valve set at 3.5 bar should be fitted downstream 
of  the  stop  tap  where  the  cold  supply  enters  the  property.    Units  must  be  fitted 
strictly in accordance with the requirements of the Local Water Undertaking who 
should be consulted prior to installation.  In the event of any difficulty please contact 
us  as  the  manufacturer.    Equipment  used  in  the  system  should  be  suitable  for  a 
working pressure of 10 bar.
A typical arrangement for the hot and cold water system is shown in Figure 3.

BALLVALVE/OVERFLOW - ALL mODELS

Because it supplies the whole of the primary/heating system a ballvalve and overflow 
must be installed in the feed and expansion cistern when the Torrent Indirect is used 
in an open vented heating system.  A ballvalve and overflow can also be fitted with 
Torrent Direct models or Torrent Indirect models fitted in sealed primary heating 
systems.

However because it only supplies the thermal store the feed and expansion cistern 
on these two appliances/systems can be filled manually if required ie through a hose 
pipe fitted with a double check valve.  In this situation an overflow can still be fitted 
if required to ensure that if a leak occurs on the internal coils it can be discharged 
safely to the outside of the building and not discharge internally from the feed and 

TYPICAL HOT AND COLD DISTRIBUTION

Check valve NOT REQUIRED unless
supply pipe services more than one dwelling

Check valve NOT REQUIRED unless
scale inhibitor is a chemical type.

Pressure limiting valve

(Not required unless mains pressure is greater than 3.5 bar)

Supply 
pipe

Second dwelling

Sink

Scale inhibitor
(where necessary)

Bath

H.B.

W.C.

BS11
Ballvalve

Figure 3 Hot and Cold Distribution Pipe Arrangement - All models

Note: The cold feed to the 

Torrent should approach 

from below to avoid heat 

creepage during idle 

periods.

expansion cistern itself.  

If a ballvalve is fitted 

a  warning/overflow  pipe  must  always  be 
fitted.

USE IN HARD WATER AREAS 
- ALL mODELS

The  patented  design  of  the  heat  exchange 
module  is  such  that  the  turbulence  through 
the coil slows down the formation of scale in 
even the hardest water conditions, at normal 
operating pressures.  However, where the water 
can be considered hard, it is recommended that 
an effective proprietary in-line scale inhibitor is 
installed.  It is important that where the supply 
to the Torrent is in mm the in-line descaler is 
also mm.  In practice servicing is not normally 
required but in hard water areas requirements 
can be considered similar to those needed for 
instantaneous or ‘combi’ appliances.
The  installation  of  the  scale  inhibitor  should 
be  in  accordance  with  the  manufacturers 
instructions and with the Water Byelaws.

PLASTIC PIPEWORK - ALL mODELS

This  appliance  is  suitable  for  use  with 
plastic  pipework  as  long  as  the  material 
is  recommended  for  the  purpose  by  the 
manufacturer and is installed fully in accordance 
with their recommendations.  We recommend 
the  use  of  barrier  pipe  for  heating  systems, 
which will  mean the  system  can  have British 
Gas service cover in regions offering this service.  
A short 300mm length of copper pipe must be 
fitted at the hot outlet from the thermostatic 
mixing valve.

WATER TREATmENT

In  all Torrent  models  treating  the  primary 
water  will  not  contaminate  domestic  hot 
water supply.

Содержание Torrent T144 DE

Страница 1: ...ins pressure hot water supply incorporating a thermal store Design Installation Instructions All models comply with the WMA specification for thermal stores Please leave these instructions adjacent to the appliance ...

Страница 2: ...upply domestic is at mains pressure it is not necessary to fit an expansion chamber pressure or temperature relief valve This information is provided to assist generally in the selection of equipment Responsibility for selection and specification of our equipment must however remain that of our customer and any experts or consultants concerned with the installation s PLEASE NOTE THAT WE DO NOT THE...

Страница 3: ...easy to incorporate into the building and will not sufferfromtheproblemsassociatedwithusing PVCu soil stacks to take the discharge from unvented cylinders TORRENT DIRECT Figure 1 Torrent Direct is an electrically heated fully packagedmainspressurehotwaterappliance It is a combination unit which incorporates a feed and expansion tank and eliminates the problems associated with a cold water cistern ...

Страница 4: ...pre set thermostat from your Local Gledhill Depot Figure 1 Torrent Direct torrent direct This is a thermal store directly heated by electric immersion heater The feed and expansion cistern is included in the finished case with the feed and vent pipe factory supplied and connected Adjustable thermostatic mixing valve To hot taps showers mm Cold mains feed mm Immersion heater Off Peak Immersion heat...

Страница 5: ...the system is designed to operate with priority to domestic hot water i e full divert then no additional allowance for hot water is required for sizing the boiler r e t a W t o H c i t s e m o D r o f e c n a w o l l A l e d o m W k r e t a W t o H c i t s e m o D r o f e c n a w o l l A e d o m t r e v i D l l u F e d o m e r a h S w o l F 0 3 1 T 0 0 7 1 T 0 3 0 0 T 0 5 3 Adjustable thermostatic...

Страница 6: ...he thermal store the feed and expansion cistern on these two appliances systems can be filled manually if required ie through a hose pipe fitted with a double check valve In this situation an overflow can still be fitted if required to ensure that if a leak occurs on the internal coils it can be discharged safely to the outside of the building and not discharge internally from the feed and TYPICAL...

Страница 7: ...0 The water level must be set correctly by adjusting the ballvalve in the F E cistern A 22mm connection is provided for the overflow warning pipe which should be no less than 20mm internal diameter and have a continuous fall 11 This should be fitted to discharge clear of the building and be situated so that any overflow can be easily observed The warning pipe should be installed in either high tem...

Страница 8: ...tors are fitted above the level of the unit F E tank water level must be 50mm min above the highest point in the primary system The boiler manufacturers instructions with regard to minimum head must be followed Feed and Vent pipes to be fitted by installer Maximum Height 6M Min 50mm All heating returns must be connected prior to primary return from the coil ...

Страница 9: ...lling loop and gauge Note F E tank on sealed system only required to fill Thermal store Primary radiator system filled from mains All heating returns must be connected prior to primary return from the coil The pressure relief valve should be fitted as close as practical to the boiler The expansion vessel should be sized in the normal way ...

Страница 10: ... cleanser such as Fernox Superfloc or Sentinel X300 to ensure that flux residues and installation debris are removed from the system When determining the quantity of cleanser required on open vented systems be sure to allow for the increased volume of water in the primary circuit due to the thermal store Commission the boiler If the boiler is range rated then adjust to the specified design heat in...

Страница 11: ...s set to maximum for all boilers DO Ensure that the water level in the expansion cistern is at least 250mm above the highest point on the radiator circuit and satisfies the boiler head required DO Insulate any exposed pipework in the Torrent cupboard DO Plumb the overflow warning pipe in 20mm minimum internal diameter tubing to discharge in a conspicuous external position using high temperature uP...

Страница 12: ...ight on the BSP male connectors to the adaptor 13 Loosen the filling cap on the Decalomat 3 to allow carbon dioxide formed in the descaling process to escape 14 Plug the Decalomat 3 to a 240V 50Hz electric supply The pump in the Decalomat will now circulate the coloured descaling solution through the heat exchanger coil of the Torrent Depending on the degree of scale formation within the coil the ...

Страница 13: ... Supplied adaptor From secondary coil Descaler reservoir Pump Descaling on site saves time and money Safe and easy to use Ensures optimum system efficiency Prolongs life of heat exchange coil Adjustable thermostatic mixing valve To hot taps showers 22mm Cold mains feed 22mm Immersion heater optional Primary Coil ...

Страница 14: ...Aquaflow Regulators Ltd Haywood House 40 New Road Stourbridge West Midlands DY8 1PA Telephone 01384 442611 Fax 01384 442612 WATER SAVINGS OPTIONS FOR SHOWERS 4 FIXING OPTIONS FOR TAPS MIXERS 1 MK Range Combined Regulators Aerator for screwing onto Taps Mixers with internal or external threads on their noses Anti Vandal models also available 2 MR05 T Range Internal Regulators Push fit into TaporMix...

Страница 15: ... set too low Is the boiler output at least 10 more than the rad loading Does the boiler flow reach temperature Is the boiler thermostat adjustable Correct Torrent thermostat setting set to 75ºC Report to the boiler manufacturer Adjust to maximum Descaling required Is heat exchanger scaled up internally Indicated by reduction of flow rate Alter pipe sizes Does the temp rise across the boiler exceed...

Страница 16: ...l a B 7 0 T F 5 0 5 0 7 3 t a o l F e v l a v l l a B 9 4 T F 6 0 5 0 7 3 3 a w a r B e v l a V g n i x i M 7 0 0 C X 7 8 5 8 3 4 e v l a v g n i x i m r o f t e k s a g g n i r e r a p S 8 0 0 C X 7 0 5 0 7 3 5 W k 3 r e t a e h n o i s r e m m I 8 7 0 B X 4 8 1 9 3 E 6 t a t s o m r e h T l o r t n o C 0 1 0 C X 7 8 9 ...

Страница 17: ...and Tanks The copper storage vessel is guaranteed for ten years and if it proves to be defective either in materials or workmanship we will either repair or supply replacement at our option with the closest substitute in the case of any obsolete product to any address in Great Britain i free of all charge during the first year after delivery by us ii thereafter at a charge of one tenth of the then...

Страница 18: ...his contract ii all other goods the subject to of any other contract between the Purchaser and us which at the time of payment of the full price of the goods sold under this contract have been delivered to the Purchaser but not paid for in full c until property in the goods supplied hereunder passes to the Purchaser in accordance with paragraph 2 above i the Purchaser shall hold the goods in a fid...

Страница 19: ...Page 19 notes ...

Страница 20: ......

Отзывы: