Page 8
INSTALLATION
Model Selection
The suggested model sizes shown in the table
opposite are based on a typical daily hot water
usage and on the assumption that the heat
pump will heat the domestic hot water to about
50°C. For higher specifi cation, an increase of one
model size should be considered.
When selecting a solar model, it is important to
check the dedicated solar volume shown in table
1 is suitable for the total fl oor area of the dwelling
and/or net area of the solar collectors to ensure
compliance with the Building Regulations.
When Stainless Lite HP is connected to both heat
pump and solar thermal systems, then during
the winter period the solar contribution will
be negligible and the heat pump will only heat
about 65% of the cylinder volume. This should
be taken into account when selecting the model.
Stainless Lite HP Model Selection Guide
Dwelling type
Suggested model
Number of
bedrooms
Number of
bathrooms and
shower rooms
Without solar
heating system
(1)
With solar heating
system
(2)
1-3
1 bathroom
HP180IND
HP180IND (F
A
=50m
2
)
2-3
1 ba
1 shower room
HP180IND
HP210IND (F
A
=65m
2
)
2-3
1 ba
2 shower rooms
HP180IND
HP250IND (F
A
=85m
2
)
2-4
2 bat
1 shower room
HP210IND
HP300IND (F
A
=110m
2
)
2-4
2 bat
2 shower rooms
HP250IND
HP400IND (F
A
=150m
2
)
3-5
2 bat
2 shower rooms
HP300IND
–
4-5
2 bat
3 shower rooms
HP400IND
–
Notes
1 Both top and bottom heat exchangers connected to heat pump circuit
2 Top heat exchanger connected to heat pump circuit and bottom heat exchanger
connected to solar circuit.
3 F
A
= Maximum fl oor area of the dwelling for compliance with the Building Regulations
INSTALLATION