Page 23
FAULT - Water Discharge Into Tundish
Clean or replace
as required
Is expansion vessel
charge pressure correct?
Replace ERV/TPRV
Replace PRV
END
START
Is pressure downstream
of pressure reducing valve
correct?
Is valve seal and seat
clean & undamaged?
Is heater operating at
less than 60ºC?
Re-set temperature
NO
YES
YES
NO
NO
YES
YES
Is ERV/TPRV
discharging?
YES
Recommission
expansion
vessel pressure
NO
NO
SERVICING AND MAINTENANCE
FAULT FINDING/SHORT PARTS LIST
SPARE PARTS LIST
Description
Quantity
Stock Code No.
1
3kW immersion element
1
SH001
2
22mm 90° compression elbow c/w/drain
1
SF003
3
Pressure and temperature relief valve 6 bar 95°C
1
SG001
4
Inlet group set at 3 bar c/w expansion relief valve set at 4.75 bar
1
SG010
5
¾” fl exible hose
1
SG003
6
18 litre expansion vessel
1
XG191
7
24 litre expansion vessel
1
XG192
8
Wall mounting bracket for 18/24 litre expansion vessel
1
XG184
9
35 litre expansion vessel
1
XG193
10
Wall mounting bracket for 35 litre expansion vessel
1
XG058
11
22mm 2 port valve (indirects only)
1
XG083
12
Junction wiring box (12 way)
1
XG129
13
Control and overheat limit thermostat
1
XG168
14
15mm x 22mm tundish
1
XG173