background image

2

3

When using this product for the first time, please pay attention to the meaning of the following warning signs 

and carefully read the safety precautions, so that you can use this equipment safely and correctly.

Warning: 

Failure to observe the precautions may result in serious personal injury 

or death.

Do not touch the equipment with wet hands to avoid electric shock; Equipment shall not be grounded through 
gas pipeline, water supply pipeline, telephone line or lightning rod, which may easily cause electric shock.

This equipment can only be installed by professional technicians or after-sales maintenance personnel, it 

may cause electric shock or fire.

Be sure to install the equipment on a solid and flat ground and take due care to prevent tipping over. If the 

ground is not solid enough or the installation location is not appropriate, it may cause the equipment to fall 

over and cause equipment damage or personal injury.
Please handle the power cord carefully to avoid short circuits or open circuits. Please turn off the power 

before pulling out the power plug. Hold the power plug carefully and pull it out. Do not pull the wires of the 

power plug. Otherwise, it may cause electric shock or fire due to the short circuit.

Don't bundle the power cord, don't press it under furniture or heavy objects, and don't get close to heat 

sources such as compressors.
Please insert the power plug into the outlet tightly to ensure firmness and reliability, so as to avoid electric 

leakage; After installation, the power plug must be within reach, so that the power plug can be unplugged in 

time in case of emergency.

Separate special outlets must be used and grounded reliably. The cross-sectional area of the copper 

2

conductor in the wall connected with the outlet must be more than 4mm . Do not lengthen the power cord 

without authorization to avoid heating or fire.

Do not use the power supply that is not specified in the equipment design, so as to avoid overheating, short 

circuit and other faults. For example, connecting 110 V rated voltage products to 220 V power supply may 

cause faults such as overheating and equipment burning. This equipment adopts a 220 V/50 HZ AC power 

supply. If the operating voltage is too low or too high, a suitable automatic voltage stabilizer must be installed 

for cooperative use.

Please place the equipment stably and avoid shaking.

Do not place the equipment in a dangerous area, and do not operate the equipment near flammable items to 

prevent explosion or fire accidents.

Warning!

Failure to observe the 

precautions may result in serious personal 

injury or death.

Attention!

Failure to observe the precautions 

may result in personal injury or equipment 
failure and related property 

losses.

Protective conductor terminal

Risk of Exploration

 This sign indicates the 

risk of explosion when using volatile and 

explosive chemicals.

Do not place it obliquely

Avoid direct sunlight

Beware of electric shock.

Beware of fire

This equipment is a precision instrument

2

Safety Instructions

Do not place the equipment in areas exposed to the sun or rain, so as to prevent danger such as short circuit 

or overheating.

Do not tilt or lay the equipment sideways, and do not impact the equipment body; Refrigeration systems are 

installed in the equipment, which is easy to be damaged by tilt or impact.

Please place the equipment in a dry and dust-free environment to avoid risks such as overheating, and short circuit.

In case of unexpected sound, smell, smoke, etc. when the power is turned on, please unplug the power in 

time and contact the manufacturer or supplier.
Please place the equipment in a dry and ventilated environment, and ensure that the equipment vents and 

instrument surfaces are not blocked or shielded by walls or other objects; Do not use it in a poorly ventilated 

environment to prevent damage caused by heat released by equipment.
It is forbidden to disassemble and modify this equipment without authorization, so as to avoid potential safety 

hazards. In this case, 

Glacier

 will not bear any responsibility for quality accidents.

It is forbidden to put inflammable and explosive dangerous goods, strong corrosive acids, alkalis and other 

items unsuitable for the equipment in the equipment.

When storing toxic, harmful or radioactive materials, please use the equipment in safe areas. Improper use 

may cause harm to human health or environment.
Metal objects such as nails or iron wires shall not be inserted into any aperture and gap or any outlet of the 

equipment, otherwise electric shock or injury may be caused due to accidental contact between the above 

objects and moving parts.
In order to ensure the normal operation and ventilation and heat dissipation of the equipment, the back, left 

and right sides of the cabinet shall be at least 30cm away from the wall, and the air inlet and air outlet must 

not be blocked by obstacles!

This equipment must be connected to a ground wire.

Note:

 Failure to observe the precautions may result in personal injury or equipment failure and

related property losses.

It is forbidden to store living animals, flowers or other items with strict temperature requirements in the 

equipment.

When the equipment is running, do not touch the inner surface of the cabinet without wearing protective gear.

Hold the handle and close the door to avoid pinching your fingers; When the equipment is not used for a long 

time, please unplug it and pack it for storage.

When restarting the equipment after power failure or power off, please check the equipment settings first, 

otherwise the stored items may be damaged due to the change of settings.

The equipment can be used for item preservation, not as production equipment!

Keep the keys properly, so as to avoid accidents when children open the door accidentally.

When handling the equipment, please be careful not to tip over the equipment, so as to prevent equipment 

damage or personal injury.

When handling, it shall be lifted from the bottom, with the inclined plane not be greater than 45°, and it shall 

be handled with care. Please use the equipment in safe areas. Improper use may cause harm to human 

health or environment.

Содержание GL-RG-12M

Страница 1: ...GL RG 4M GL RG 12M GL RG 16M GL RG 23M OPERATION MANUAL Applicable product model www aegisfridge com ...

Страница 2: ...roduct composition and overview 6 Operating Instructions 6 1 Function Introduction 6 2 Optional function 7 Maintenance and Service 7 1 Equipment Maintenance 7 2 Equipment Discontinuation 7 3 Maintenance Replacement and Recovery of Rechargeable Batteries 8 Troubleshooting and Maintenance Services 9 Specifications 10 Packing List 11 Electrical Schematic Diagram 1 2 4 4 4 4 5 5 6 7 10 10 19 19 20 19 ...

Страница 3: ...er products For your safe and convenient use and reasonable maintenance of the equipment please read the Operation Instructions carefully before use and keep it properly for reference The equipment operator can copy some chapters of this operation manual but only for internal use for example to instruct the user how to deal with emergencies These chapters are clearly marked in the catalog of the m...

Страница 4: ...utlet tightly to ensure firmness and reliability so as to avoid electric leakage After installation the power plug must be within reach so that the power plug can be unplugged in time in case of emergency Separate special outlets must be used and grounded reliably The cross sectional area of the copper 2 conductor in the wall connected with the outlet must be more than 4mm Do not lengthen the powe...

Страница 5: ...r any outlet of the equipment otherwise electric shock or injury may be caused due to accidental contact between the above objects and moving parts In order to ensure the normal operation and ventilation and heat dissipation of the equipment the back left and right sides of the cabinet shall be at least 30cm away from the wall and the air inlet and air outlet must not be blocked by obstacles This ...

Страница 6: ... cold and heat sources and strong electromagnetic interference which will affect the normal operation of the control system and directly damage the system in severe cases 4 2 Installation Site Figure N and E ends cannot be connected In order to operate the equipment normally and obtain the best performance level the installation site of the equipment shall meet the following requirements ò It cann...

Страница 7: ...rt both ends of the handle cover into the corresponding grooves of the handle seat and then press it to close it 4 3 Preparation before use 4 4 First Power on When using the equipment for the first time please follow these steps 1 After the equipment is placed leveled and cleaned it shall stand for more than 24 hours and then power it on to ensure the normal operation of the equipment 2 Under no l...

Страница 8: ...reached Electrical appliances without production license shall not be used inside the equipment Do not change the set temperature frequently in a short time otherwise the expected setting effect may not be achieved due to the large temperature inertia Ensure that there is a certain air circulation space around the cabinet when putting in items especially do not block the temperature sensor in the ...

Страница 9: ...M Figure II GL RG 4M USB interface Door body Display panel Door lock Test hole Cabinet Caster Adjust feet Power switch Remote alarm interface Rs485 interface Door lock Test hole Door handle Cabinet Adjust feet Caster Door body USB interface Display panel ...

Страница 10: ...8 Figure III Figure IV Caster Door handle Door body Cabinet Caster Door lock Adjust feet Steel wire shelf Test hole Printer optional Display panel power switch on the back USB interface ...

Страница 11: ...he product consists of cabinet door glass door structure or foam door structure refrigeration system and control system Scope of application It is suitable for storing items in hospitals pharmacies epidemic prevention stations research institutions biopharmaceuticals and other units Figure V Steel wire shelf Door body Caster Cabinet Test hole Printer optional Display panel power switch on the back...

Страница 12: ...ff When the printer is working the indicator is on f Door heating indicator When the door heating is turned off the door heating indicator is off When the door heating is turned on the door heating indicator is on g Refrigeration indicator If the compressor is in working condition the refrigeration indicator is on If the compressor is in a shutdown state the cooling indicator is off h Mute indicat...

Страница 13: ...y for 3 seconds to import the data of the USB flash drive in 12 months 5 is a down key In parameter setting mode move to the previous parameter or decrease the parameter value For example when setting the set temperature reduce the set temperature When setting the parameter value long press the down button and the parameter will decrease rapidly 6 is a print key The system can keep 7 days of data f...

Страница 14: ...0 5 0 Temperature setting 2 H 0 0 10 0 5 0 Set value of high temperature alarm set H When H 0 High temp alarm is disabled When the alarm is over high temp alarm set H1 will be displayed on the controller 3 L 0 0 10 0 4 0 Set value of low temperature alarm set L When L 0 Low temp alarm is disabled When the alarm is below low temp alarm set L1 will be displayed on the controller 4 Pt 0 240 min 20 Pr...

Страница 15: ...arm L1 Low temperature alarm H2 Alarm for high ambient temperature H3 Condenser overheat alarm do Door opening alarm PF Power failure alarm bL Battery low alarm Er The recorder is not connected LoF Battery low alarm EE Communication failure 5 Alarm display ...

Страница 16: ...t above the key is off e PRINT optional The system can keep 7 days of data for printing Press the print key to print the temperature within the set time period f In parameter setting mode reduce the parameter value For example when setting the set temperature reduce the set temperature When setting the parameter value long press the down button and the parameter will decrease rapidly g In paramete...

Страница 17: ...d displays LoF the recorder is not started Meanwhile press and key for 3s and LoF disappears the recorder is started 2 Function setting of Type B control panel 1 Power on and turn on the power switch on the back of the cabinet and the equipment will enter the working state 2 User parameter settings Unlock In normal operation state simultaneously press and key for 3s and the digital tube displays t...

Страница 18: ...is opened and closed again during the heating period the heating time will be updated again Mode 2 When the compressor runs Heater is on When the compressor stops the heater Will automatically off after one min Mode 3 When the humidity in the cabinet is more than 80 the door heating is on and when the humidity in the cabinet is moderately less than 60 the door heating is off Mode 4 Door heating is...

Страница 19: ...ting paper has been installed at the factory When the paper is used up after a long time you may purchase the same paper for installation The installation steps are as follows Click the cylindrical button on the printer to open the cover of the printer Put the printing paper into the printer box and pull the paper head of the roll so that the paper slightly exposes from the upper port of the box c...

Страница 20: ...and RS485 interface The remote alarm terminal is installed on the back of the cabinet and the alarm signal is output by the terminal The load bearing capacity of the terminal is 30V 2A DC Users can choose normally open normally closed and common terminals according to their own needs 18 RS 485 ...

Страница 21: ...month and the power lock switch should be turned on so that the equipment can run for a period of time to complete charging and each charging time should be no less than 24 hours When the working power supply is interrupted the power lock switch of the equipment shall be turned off in time otherwise it will cause power loss in battery and even permanent damage to the battery in severe cases The ma...

Страница 22: ...roduct may fail Please observe the operation of equipment in time during use If there is any abnormality please check and handle it according to the following table first If the abnormality can t be changed please inform our service center in time and we will serve you wholeheartedly to avoid losses Fan motor replacement time about 6 years Service life of the product 10 years Notes 20 After the eq...

Страница 23: ...540X764 YC 130L 16 32 C N R134a 110g 220 230V 50 2 8 C 130 155 51 625X650X810 YC 315L 16 32 C N R600a 22g 220 230V 50 2 8 C 315 285 87 673X650X1762 YC 395L 16 32 C N R600a 25g 220 230V 50 2 8 C 395 290 95 673X650X1992 YC 395EL 16 32 C N R600a 25g 220 230V 50 2 8 C 395 250 89 673X650X1992 YC 400L 16 32 C N R290 65g 220 230V 50 2 8 C 400 500 116 645X700X2016 YC 525L 16 32 C N R290 75g 220 230V 50 2 ...

Страница 24: ...mity Accessory package Key The door handle accessory applies to models YC 725L YC 1015L YC 1015EL and YC 1505L Keys apply to models YC 55L YC 55EL YC 75L YC 75EL YC 130L YC 315L YC 395L YC 395EL YC 400L YC 525L YC 725L and YC 1505L The specific packing list shall be subject to the physical objects received 1 1 1 2 Operation Manual ...

Страница 25: ...EL YC 400L YC 525L YC 725L YC 1015L YC 1015EL YC 1505L Applicable to YC 130L The technical data and electrical schematic diagram shall be subject to the nameplate on the product and the electrical schematic diagram in case of any improvement of the product design We sincerely apologize for any inconvenience that might be caused ...

Отзывы: