6.2 Optional function
1
.
Printer
Automatic printing:
When the printing interval Pt is not 0, the printer prints the current data every Pt minutes.
Manual printing:
When the key is unlocked and the working voltage is normal, press the print key to display "P01" by the digital tube,
press the up key or down key to adjust "P00
~
P07." Press the set/mute multiplexing key or print key, and the printer will
cancel the manual printing (P00) or print the data recorded in the previous days (1 ~ 7), with the data interval same as
the automatic printing interval.
Printing paper installation:
The printing paper has been installed at the factory. When the paper is used up after a long time, you may purchase the
same paper for installation. The installation steps are as follows:
①
Click the cylindrical button on the printer to open the cover of the printer;
②
Put the printing paper into the printer box and pull the paper head of the roll so that the paper slightly exposes from
the upper port of the box cover after the box cover of the printer is closed;
;
③
Close the box cover.
4. Parameter display
9
No.
Menu
item
Parameter Range
Suggested
settings
Remarks
Hardware version
Software version
Temperature setting
Set value of high temperature alarm set+H; When
H =0, High temp alarm is disabled; When the
alarm is over high temp alarm set, H1 will be
displayed on the controller
Set value of low temperature alarm set-L; When L
=0, Low temp alarm is disabled; When the alarm is
below low temp alarm set, L1 will be displayed on
the controller
Print interval
Upper limit of ambient temperature alarm
Mode 1: It shall be judged as once after the door is
opened and closed once and heated for 5min (time
setting). If the door is opened and closed again
during the heating period, the heating time will be
updated again;
Mode 2: When the compressor runs, Heater is on;;
When the compressor stops, the heater Will
automatically off after one min
Mode 3: When the humidity in the cabinet is more
than 80%, the door heating is on, and when the
humidity in the cabinet is moderately less than 60%,
the door heating is off;
Mode 4: Door heating is always on;
Mode 5: Door heating is always off.
1.(Set to 4 when
the door is with
condensation)
(Set to 1 when
the door is a
glass door)
(Set to 5 when
the door is a
foaming door)
1. Automatic
heating mode 1
2. Automatic
heating mode 2
3. Automatic
heating mode 3
4. Always on
5. Always off
PS1
User menu password settings
Alarm Code
Error Description
H1
High temperature alarm
L1
Low temperature alarm
H2
Alarm for high ambient temperature
H3
Condenser overheat alarm
do
Door opening alarm
PF
Power failure alarm
bL
Battery low alarm
Er
The recorder is not connected
LoF
Battery low alarm
EE
Communication failure
5. Alarm display
20
Pt
6
0-240 min
20.0-50.0
℃
40.0
tH1
7
5.0
H
4
0.0-10.0
0.0-10.0
5.0
L
5
-
b1
1
-
-
-
b2
2
20
Set
3
0.0-10.0
P1
8
0000-9999
0005
5.0