Installation
46
Cod. 598250
Rev. 09/0918
3.6.5. External dosing electrical connection (RMS610 / REM025 only)
Signal conductor
If using single-wire conductors, these must be encased within
a safety conduit.
The conductor must be affixed to the inlet opening of the
machine using a secure connection appropriate for the type of
conductor.
The conductor must be protected against traction, crushing
and friction.
Additional specifications for the conductor: must comply with
the statutory regulations of the country in which it is to be
installed.
Connection of the dispenser equipment to the washer
(Fig.
3.17).
Disconnect and mechanically lock the external automatic
switch.
Open the machine’s terminal box.
Fix a conductor bracket (not supplied with the washer) to the
inlet hole and secure the conductor in place.
Connect the dispenser signal conductor to the terminal board
A
, according to the functions specified on the corresponding
label. (This terminal board is identified on the electrical
schematic as A-4)
Connect the electrical supply of the dispenser equipment to
an electrical inlet separate from the washer. The electrical
protection of the dispenser equipment must be separate from
the washer protection.
Fig. 3.17
NEVER CONNECT THE DISPENSER EQUIPMENT SUPPLY TO THE WASHER
3.7. External dosing hoses connection
The external dosing inlets are perforated and protected by a
tube cap.
Refer to dimensions and dosing inlets diameter in
INSTALLATION SPECS, section
1.4
.
To connect the product cables:
Locate the dosing inlets in the back of the machine.
Remove the tube caps and save them.
Connect the hoses to the nipples
A
on the manifold (Fig.
3.18).
Fasten the dosing hoses to the washing machine with the
appropriate clamps.
Fig. 3.18