Installation
38
Cod. 598250
Rev. 09/0918
RMS/RMG613, RMS/RMG617; RMS/RMG623, RMS/RMG628, REM/RMG033, REM/RMG040, REM/RMG055,
REM/RMG070 models
Disconnect and mechanically lock the external automatic switch.
Open machine terminal box at the rear panel. Remove the support cover of the entry switch to the washer.
On the entry hole of the electrical supply (
E
identified in figure 1.4) install a lock mechanism (not supplied
with the washer) to fasten the cable or cable pipe protector, depending on the cable and pipe protector used.
Refer to dimensions and connection diameter in INSTALLATION SPECS, section
1.4
.
Connect the wires directly to the switch breaker (Fig. 3.9).
The wire connection sequence to the main switch varies according to the machine connection and the power
supply. This connection is indicated on the label posted next to the main switch.
In models
RMS/RMG628
and
REM/RMG070
, pass the conductor through the cable tie (
A
) and secure it as
shown in Fig.3.8.
Fig. 3.8
LABEL
PE/GND
L1
L2/N
PE/GND
L1
L2/N
PE/GND
L1
L2
L3
PE/GND
L1
L2
L3
N
SUPPLY
LINE
L1
L2
L1
N
L1
L2
L3
L1
L2
L3
N
RMS/RMG
REM/RMG
CONNECTION
Fig. 3.9