Dry Contact Control Module
Model 98GC104DC (Transmitter)
The Dry Contact Control Module allows the user to interface their Dry Contact Systems with our Glink Controllers,
this module will accept the signal of Retract, Stop and Extend commands from the Relays of the Dry Contact
Systems and it will send an RF signal to a programmed Glink Controller or Remote Motor.
The unit is powered by 12VDC and provides connections to the Dry Contact System.
Figure 1
Programming steps
NOTE:
1.
Before starting this procedure the Receiver must be without power (OFF) for at least 10 seconds.
2.
During the programming function the interval between each step required must be less than 10 seconds
1.
PROGRAMMING THE 98GC104DC TO A RECEIVER
a.
Connecto the Dry Contact Control Module(98GC104DC) to 12 volt DC
b.
Make sure that the
Receiver
is powered on
c.
Press the program button on the
Receiver
: the Green LED of the Receiver will start blinking
d.
Press STOP on the
Receiver
: The Green LED will stop blinking and stay on solid
e.
From the Signal Cable of the 98GC104DC, select the (WHITE and RED wires) put those two
wires together for three seconds: The Green LED will turn off.