Figure 2: Connection example, energy sensor

(4) Monitored consumer

o

Connect energy sensor as shown in the connection example (Figure 2).

o

Insert energy sensor in the appliance box in such a way that the 

Prog

 button and status

LED are visible.

o

Perform commissioning.

o

Mount the cover.

4.2 Commissioning

DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
During commissioning, cover the parts carrying voltage on the device and in
their surrounding area.

Integrating an energy sensor into the project

The energy sensor must be read in using a device search of the eNet Server and integrated into
the project.
To do this, the eNet server must be connected correctly and connected to a computer (see the
instructions of the eNet server).

o

Start the commissioning interface of the eNet server. Create or open the project into which
the energy sensor is to be integrated (see product documentation of the eNet server). 

o

Start the device search in the commissioning interface of the eNet Server.

o

Press button 

Prog

 (2) for longer than 4 seconds.

The status LED (4) flashes after 1 seconds. The energy sensor is in programming mode for
approx. 1 minute.
The eNet server finds the energy sensor and displays it on the commissioning interface.
The status LED of the energy sensor goes out.

o

Add the energy sensor to the device location using the commissioning interface.

Removing an energy sensor from the project

o

In the commissioning interface of the eNet server, delete the energy sensor from the
current project (refer to the product documentation of the eNet server).
The energy sensor is removed from the project and the parameters reset to the default
setting.

32581512

10864964

11.04.2017

3/8

Wireless energy sensor, 1-gang Mini

Содержание 5471 00

Страница 1: ...vice components Figure 1 Energy sensor 1 Status LED red 2 Button Prog 3 Terminals 3 Function Intended use Energy sensor for radio transmission of voltage current and energy values Operation with eNet server Mounting in appliance box according to DIN 49073 with a suitable cover Mounting in surface mounted housing or built in housing accessory for false ceilings i The energy sensor is not officially...

Страница 2: ...at least one minute Default setting Time controlled transmission transmission interval 15 minutes Event controlled transmission Rel threshold value effective power 10 Abs threshold value effective power 1 W Transferred characteristic electric values Current Voltage Average effective power Interval for average formation configurable between 0 2 300 s Apparent power Fundamental oscillation idle powe...

Страница 3: ...e commissioning interface of the eNet server Create or open the project into which the energy sensor is to be integrated see product documentation of the eNet server o Start the device search in the commissioning interface of the eNet Server o Press button Prog 2 for longer than 4 seconds The status LED 4 flashes after 1 seconds The energy sensor is in programming mode for approx 1 minute The eNet...

Страница 4: ... sleeve 0 75 2 5 mm Dimensions Ø H 53 23 mm Radio frequency 868 0 868 6 MHz Transmission capacity max 20 mW Transmitting range in free field typ 100 m Measuring ranges Current 0 mA 16 A Accuracy current 0 5 of the current value and 8 mA Voltage 207 250 V Accuracy voltage 0 5 of curr val Transmitted power and output values Effective output 4000 4000 W Apparent output 0 4000 VA Idle output 4000 4000...

Страница 5: ...s Parameters Setting options Basic setting Explanations Active energy 1073741823 1073741823 Wh Basic setting 0 Wh Current value Displays the currently cumulated active energy The value can be reset to 0 or set to any other value Extended channel settings Parameters Setting options Basic setting Explanations Manual commissioning On Off Basic setting On Blocks manual commissioning for the device cha...

Страница 6: ...he most recently transmitted effective output value If the percentage change entered here is exceeded then all the measured values are resent Abs threshold value effective power 0 2000 W Basic setting 1 W A lower threshold value of the effective power can be entered here to avoid frequent transmission in the lower power range Event controlled transmission is only active above this threshold value ...

Страница 7: ...source e g a photovoltaic system feeding in energy Cause 2 The energy sensor is connected in reverse polarity Connect the energy sensor with the correct polarity i If negative reactive power values are displayed this is a capacitive idle power Positive values show an inductive reactive power 5 4 Accessories Installation adapter Mini housing Order No 5429 00 eNet Server Order No 5301 00 5 5 Conform...

Страница 8: ... Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de 32581512 10864964 11 04 2017 8 8 Wireless energy sensor 1 gang Mini ...

Отзывы: