Software
Order No. 5201 00
Page 23
Object
Name
Function
Type
DP type
Flags
51
Alarm control unit
Programming
mode status
1 bit
1.011 status
C, R, T
Show KNX alarm communication objects: Active. Object for transmitting the programming mode. "1"
means programming mode is activated, and "0" means that programming mode is deactivated.
Object
Name
Function
Type
DP type
Flags
1001
Alarm control unit
Configuration
mode
1 bit
1.011 status
C, R, T
Object for reading configuration mode. "1" means configuration mode is activated, and "0" means
that configuration mode is deactivated.
Object
Name
Function
Type
DP type
Flags
1002
Alarm control unit
Learning
mode
1 bit
1.011 status
C, R, T
Object for transmitting learning mode. "1" means learning mode is activated, and "0" means that
learning mode is deactivated.
Object
Name
Function
Type
DP type
Flags
1025
Alarm control unit
Test mode
1 bit
1.011 status
C, R, T
Object for transmitting test mode. "1" means test mode is activated, and "0" means that test mode
is deactivated.
Object
Name
Function
Type
DP type
Flags
1101,
1201,
1301,
1401
Main security area, security
area 2,
security area 3,
security area 4
Status
1 bytes
5.010 meter
pulses (0..255)
C, R, T
Object for transmitting the current arming state.
00h
Disarmed
The security area is unprotected.
01h
Internally armed
The security area’s perimeter is secured.
02h
Externally armed
The security area is secured throughout.
03h
Arming externally
Full security is being established.
05h
Entry delay
System disarming.
Object
Name
Function
Type
DP type
Flags
1102,
1202,
1302,
1402
Main security area, security
area 2,
security area 3,
security area 4
Vestibule
devices arm-
ing ready
1 bit
1.002 Boolean
C, R, T
Objects for reading whether the entry components are ready. “1” means ready, “0” means not ready.