GIRA
Info
Smoke detector
Instructions for Installation
Smoke detector
45/00
Seite: 2 von 5
Minimum protection: one smoke detector in
the hallway or in the stairwell of each floor
Optimum protection: one smoke detector in
each bedroom and living room
Unsuitable installation sites
In order to prevent false alarms and
malfunctions, do not install the smoke detector:
•
in rooms where a large amount of steam,
dust, or smoke are produced under normal
circumstances.
•
near hearths and open fireplaces.
•
near ventilation shafts, since the stream of
air could possibly prevent smoke from
reaching the detector.
•
near fluorescent and energy-saving lamps,
since the starter can trigger false alarms
due to the electrical fields caused by
turning the lamp on (minimum distance:
50 cm).
•
in rooms where temperatures are below
+5°C or above +45°C.
Installation and commissioning
Remove the two spacers from the socket.
Otherwise, locking of the smoke detector is
not possible.
1. Install the socket
e
with the included
installation material.
2. Use the spacers
f
, if the linking line of
several smoke detectors is "surface-
mounted".
3. If needed, carry out the appropriate steps to
link several smoke detectors.
For this, read the chapter "Linking smoke
detectors".
4. Connect the 9V block battery
i
to the battery
connection and insert the battery into battery
bracket.
5. Stick the smoke detector
c
into the socket
and lock it by turning slightly clockwise.
Caution:
If no battery is inserted, the smoke
detector cannot be fixed in the socket.
6. Carry out a function test.
c
Smoke detector
d
Connection block
e
Socket
f
Spacers
g
Plug
h
Screw
i
Battery (9V)
j
Test button