background image

GIRA

 

Info

 

 

Smoke detector 

Instructions for Installation 

 

 

Smoke detector 

45/00 

Seite: 1 von 5 

Smoke detector

 

Art. Nr.: 0869 00 / 04 

 

Product characteristics at a glance 

  Battery-operated smoke detector with photoelectric scattered light principle 

  Automatic self test of the smoke evaluation 

  Ability to link up to 40 smoke detectors 

  Loud, pulsing warning signal at approx. 85 dB (A) 

  Battery change indicator 

 Contamination/disturbance 

indicator 

  Integrated test button for testing the function 

  Battery compartment check: if no battery is installed in the smoke detector, it cannot be locked into 

the socket 

  Polarity reversal protection: the device cannot be destroyed due to incorrect battery connection 

  VdS-recognition: G 200 121 

 

Safety Indications 

  Never paint over the smoke detector. 

  Smoke detectors only detect the smoke of a fire, but not the flames themselves. 

  Smoke detectors do not extinguish a fire. When the alarm sounds, search for the source of the fire 

and call the fire department if necessary. 

  Do not use rechargeable batteries (accumulators) or power packs for power supply. They can 

cause disruptions or the premature failure of the device. 

  The smoke detector produces a very loud and shrill sound, which can damage hearing. For this 

reason, please observe a safety distance of 50 cm during the function test. 

  The smoke detector only monitors a defined area in the vicinity of the installation site. Install 

enough detectors to cover the entire living area and ensure optimum protection. 

  People under the influence of alcohol or drugs may not be awakened by the signal sound. 

 

Installation site 

Smoke detectors should preferably be installed outside the door of or in bedrooms so that you will be 
awakened by the smoke alarm at night. In buildings with several floors, at least one smoke detector 
should be located on each floor. 
 
The smoke detector will have optimum detection characteristics if it is installed under the ceiling in the 
center of the room. If this is not possible, keep a distance of at least 50 cm from the wall. 
If the smoke detector is installed in the kitchen, you should locate the device as far away from the 
cooking zone as possible to prevent false alarms due to steam. 
 
In large houses, you should use several, linked smoke detectors to cover the entire living area. If 
smoke is detected by one smoke detector, it sets off an alarm and activates all connected smoke 
detectors, which then also sound the alarm. Thus, you will be awakened during the night by your 
linked smoke detector in the bedroom if the smoke detector in the cellar detects smoke. 