o
Route the sensor cable behind the supporting plate (14) and through the cable duct to the
connecting terminal (13) (Figure 9).
o
Connect the cable (see "Connecting sensors to terminal block")
Connecting sensors to terminal block
Figure 10: Connection to the terminal block
o
Connect sensors as shown in connection illustration (Figure 10). The sensor cables are
identified as follows:
For the sensors, the "earth" is identified.
For the adapter and the extension cable, the "sun" is identified. The "earth" is the middle
cable.
i
Interchanging the connections will result in malfunctions.
i
If the sun and glass break sensor are used at the same time, an adapter must be used.
The adapter is connected to a cover with sensor evaluation or to the insert via the
3-pole terminal block. The adapter has two sockets for connecting the sensor plug.
Plugging the sensor cable into the cover
Figure 11: Sun sensor on the cover
32545312
10499098 I00
17.05.2011
7/8
Blind control system
Blind controller insert DC 24 V